Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Rheem furnace 6 flashes means a rollout switch trip. Check vent blockage, inducer draft, burner flame, gas pressure, and heat-exchanger safety.
Rheem furnace 6 flashes means a rollout switch trip. Check vent blockage, inducer draft, burner flame, gas pressure, and heat-exchanger safety.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
What it means: Six flashes on a Rheem or Ruud furnace diagnostic LED indicates an open rollout switch. The rollout switch (rollout limit) is a manual-reset thermal safety device mounted at the burner assembly. It trips when flame escapes the burner box — a condition called flame rollout — which means combustion is occurring outside the designed combustion path. Rollout is a serious condition. Unlike the high limit, the rollout switch will not auto-reset — it must be manually reset after the cause is identified and corrected.
Clear any flue blockage and restore full combustion airflow. If the inducer motor is the cause (low RPM, won’t start), replace the inducer motor or its run capacitor.
Once the cause is corrected, locate the rollout switch on the burner bracket. It is a round, bi-metal snap-disc device with a small red or white reset button on top. Press firmly until you hear/feel a click. If the button depresses but springs back without clicking, the switch has failed and must be replaced — do not continue operating the furnace.
Restore power and observe a full heating cycle. Watch through the sight glass that flames stay contained within the burner ports.
| Part | Where to Buy |
|---|---|
| Rollout limit switch | RepairClinic, SupplyHouse |
| Inducer motor assembly | RepairClinic, Grainger |
| Inducer motor capacitor | Grainger |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Any rollout fault where heat exchanger damage is suspected requires a licensed HVAC technician immediately. Do not operate the furnace until cleared. Rollout is one of the few furnace faults that presents a direct CO and fire risk. If you can’t identify a clear, non-heat-exchanger cause, call a tech before resetting anything.