Thermocouple
Common pilot and ignition part on gas water heaters.
Noritz tankless water heater Error Code 20 means low water flow or a water flow sensor fault. Learn causes, diagnostic steps, and how to fix Noritz Error 20.
Noritz tankless water heater Error Code 20 means low water flow or a water flow sensor fault. Learn causes, diagnostic steps, and how to fix Noritz Error 20.
Likely parts to price
Common pilot and ignition part on gas water heaters.
Price this on no-light and ignition failure symptoms.
Common fault-code part. Confirm model and sensor style first.
Higher-cost part to price after confirming supply, venting, and ignition checks.
Error Code 20 on Noritz tankless water heaters (NR, NC, NRC series) means the unit has detected insufficient water flow to safely operate. Noritz units require a minimum flow rate to activate the burner — without adequate flow, the heat exchanger can overheat. Error 20 prevents this.
| Cause | Likelihood |
|---|---|
| Clogged inlet filter screen | Very High |
| Partially closed cold water shutoff valve | High |
| Low water pressure at the unit | High |
| Scale or debris blocking the flow sensor | Medium |
| Failed flow sensor | Medium |
| Scale in hot water piping or fixtures | Low |
Step 1 — Clean the inlet filter screen This is the most common fix:
Step 2 — Check cold water supply pressure
Step 3 — Inspect the flow sensor
Step 4 — Test the flow sensor
Step 5 — Check entire hot water distribution
Noritz units reset automatically when flow is restored:
| Part | Notes |
|---|---|
| Flow sensor assembly | Noritz part 100-194-0001 or model-specific |
| Inlet filter screen | Noritz part or equivalent mesh screen |
| Pressure regulator | If incoming pressure is consistently low |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: If Error 20 occurs intermittently rather than constantly, check for partially open fixtures or a check valve that is sticking. Intermittent flow loss below the minimum triggers Error 20 briefly before flow returns.