Error code 16 on a Noritz tankless water heater indicates an over-temperature shutdown — the outgoing water temperature exceeded the unit’s maximum safe limit. The control board detected that the heat exchanger outlet temperature reached an unsafe level (typically above 85°C / 185°F for most residential models) and cut the burner to protect the heat exchanger, plumbing, and users from scalding.
| Part | Notes |
|---|---|
| Outlet thermistor | Noritz OEM NTC sensor; match model series |
| Inlet filter screen | Clean or replace; inexpensive maintenance item |
| Descaling solution | White vinegar or commercial tankless descaler |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Gas pressure measurement and adjustment require a licensed gas technician. Persistent code 16 after descaling and thermistor replacement may indicate a heat exchanger that has been damaged by scale and needs replacement — a licensed plumber should assess.