Nest thermostat E73 means it can't detect power on the Rc cooling wire. Check the furnace fuse first — a blown fuse causes most E73 errors.
Nest thermostat E73 means it can't detect power on the Rc cooling wire. Check the furnace fuse first — a blown fuse causes most E73 errors.
Likely parts to price
Common fix for smart thermostat power, Wi-Fi, and delayed-start problems.
Price this only after confirming low-voltage power at the control board.
Useful when adding a common wire or repairing damaged low-voltage wiring.
Relevant when remote sensor communication or room-reading faults match.
E73 on a Nest thermostat means it can’t detect 24VAC power on the Rc wire — the wire that powers the cooling side of your HVAC system. This is one of the most common Nest errors after a thermostat swap or HVAC service call. The fix is usually a blown fuse at the furnace, which costs about $2 and takes 5 minutes.
The Nest needs 24VAC power from your HVAC system to operate. Most HVAC systems have two 24V transformers — one for heating (Rh wire) and one for cooling (Rc wire). E73 specifically means the Rc wire isn’t carrying the expected voltage.
Step 1: Check the fuse at the furnace (most common fix)
Step 2: Check the Rc wire connection
At the Nest base (the part that stays on the wall):
At the furnace: 3. Find where your thermostat wires connect to the control board. Look for the terminal labeled “Rc” (sometimes labeled “R” if the system uses a single R terminal for both heating and cooling). Confirm the wire is seated and the terminal screw is snug.
Step 3: Add a C-wire or Nest Power Connector
If you don’t have a C-wire connected (a “Common” wire that completes the 24V circuit), the Nest may have intermittent power issues that manifest as E73.
The simplest fix is the Nest Power Connector (sometimes called the C-wire adapter) — Google makes it specifically for this situation. It connects to your HVAC equipment and provides power to the Nest without running a new wire.
Step 4: Test the transformer
With the system powered on, use a multimeter set to AC voltage. Measure between the R and C terminals at the furnace control board (or at the thermostat wiring block). You should read 24–28 VAC. Zero volts means the transformer has failed.
If replacing the fuse and checking wiring connections doesn’t fix E73, the 24V transformer at the furnace or the HVAC equipment itself has a problem. An HVAC technician can test the transformer and trace the wiring quickly.