Skip to content
Industrial Error Code Fixes
Go back

Navien E515 Error Code - Causes & Fix

2 min read
⚡ Quick Answer

E515 signals an abnormal PCB condition on your Navien tankless. Most common fix is reseating connectors or replacing the main control board.

Difficulty Pro recommended
Est. time 1-3 hrs

Error code E515 (or 515-09) on your Navien tankless water heater means the control board has detected a fault in its own operation or communication path. The unit may lock out to protect itself. Some models display subcodes that point to specific circuits like the ignitor, fan motor, monitoring device, or dual venturi assembly. Because this is an internal control fault, the heater typically stops heating until the problem is cleared or the defective component is replaced.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Verify the full code and subcode displayed on the unit, noting your exact model number, because Navien code families vary by model series.
  2. Power-cycle the heater by switching off the main power or unplugging the unit for 5 to 30 minutes to clear transient faults, then restart and observe.
  3. Turn off power and inspect the main PCB wiring harness for loose, corroded, or heat-damaged connectors, reseating every plug firmly and checking for pin fit.
  4. Examine the control board visually for burn marks, discoloration, swollen components, or odor that indicate surge damage or board failure.
  5. Check the subsystem named by your subcode if applicable: inspect ignitor circuit, fan motor wiring, or dual venturi monitoring device connections and operation.
  6. Replace the main PCB if visual damage is present, connectors are intact, and the code returns after a power cycle, using the correct board revision for your model.
  7. Re-test the unit through a full ignition and heating cycle after repair to confirm the E515 clears and the heater operates normally without recurrence.

Parts Often Needed

PartNotes
Navien main PCB / control boardAmazon | Match your model number exactly. Field-reported part number 30027274B (PCB GWC303-6M V12-2) applies to specific models only.
Ignitor assemblyAmazon | Only if your subcode points to ignitor communication fault and visual inspection or resistance test shows failure.
Fan motorAmazon | Required if subcode indicates fan circuit abnormality and motor does not spin freely or draws incorrect current.

When to Call a Pro

Call a licensed plumber or Navien-certified technician if you are uncomfortable working with 120V or 240V electrical components, if the error returns after reseating connectors and power-cycling, or if you lack the tools to safely remove and replace the control board. PCB replacement requires matching the exact board revision to your model and may involve firmware considerations. If your unit is under warranty, contact Navien or your installer before attempting any repair to avoid voiding coverage.


Share this post on:

Previous Post
Navien Alarm 415 - Causes & Fix
Next Post
Navien E038 Error Code - Causes & Fix