Thermocouple
Common pilot and ignition part on gas water heaters.
Troubleshoot Navien error code E010 on boilers and tankless water heaters with checks for gas, venting, sensors, pumps, ignition, and service limits.
Likely parts to price
Common pilot and ignition part on gas water heaters.
Price this on no-light and ignition failure symptoms.
Common fault-code part. Confirm model and sensor style first.
Higher-cost part to price after confirming supply, venting, and ignition checks.
Elements, thermostats, thermocouples, gas valves, and anode rods in stock when the local supply house is closed.
Troubleshoot Navien error code E010 on boilers and tankless water heaters with checks for gas, venting, sensors, pumps, ignition, and service limits.
Navien error code E010 indicates an air pressure sensor (APS) fault. The APS is a differential pressure sensor that monitors the draft produced by the combustion blower to verify adequate airflow before and during combustion. If the measured pressure differential is outside the expected range — either too low (insufficient draft) or reading zero when the fan is running — the unit faults on E010 and shuts down. This fault prevents the unit from firing without proper combustion air, protecting against combustion gas spillage. E010 is common in winter when intake or exhaust vent terminations become blocked.
| Part | Notes |
|---|---|
| Air pressure sensor (APS) | Navien part; match to unit model — setpoints differ by BTU rating |
| APS tubing (replacement) | Cheap; replace if cracked or contaminated |
| Combustion blower assembly | Replace if blower speed is confirmed low under load |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the vent terminations are clear, the APS hoses are intact, and the blower is running at full speed but E010 persists, the APS calibration or the blower’s actual pressure output requires measurement. This requires a manometer and familiarity with Navien’s pressure specifications.