Igniter
Price the ignition part only after confirming the model number and connector.
Navien E001 guide for no-ignition faults, gas supply, igniter checks, flame sensing, condensate issues, tankless resets, and pro repair limits.
Navien E001 guide for no-ignition faults, gas supply, igniter checks, flame sensing, condensate issues, tankless resets, and pro repair limits.
Likely parts to price
Price the ignition part only after confirming the model number and connector.
Common lockout part on gas heat and burner systems.
Relevant for pilot-safety and older gas appliance faults.
What it means: Navien error code E001 indicates a no-ignition fault. The Navien control board initiated an ignition sequence — energizing the igniter and opening the gas valve — but the flame sensor did not detect a confirmed flame within the ignition trial period. After multiple failed attempts, the unit locks out with E001. This code applies to both Navien NR/NRC-series tankless water heaters and NCB-series combi-boilers. The unit will not fire until the fault is reset by pressing the power button or cycling the unit off and on.
Air purging resolves E001 on new installations and after gas outages — press reset repeatedly (5–10 times) to allow the unit to pull through the air-filled line. Patience is required.
For dirty igniters: clean the spark electrode with 320-grit sandpaper, ensuring the gap between the electrode tip and ground plate is 3–4mm (per Navien spec). For dirty flame rods: clean the rod with emery cloth.
If the igniter electrode is cracked or the flame rod is corroded through: replace the igniter/flame sensor assembly. Navien sells these as a combined assembly for most NR and NCB models.
Low gas pressure requires a licensed plumber or gas tech to inspect the gas piping supply and meter capacity.
| Part | Where to Buy |
|---|---|
| Navien igniter / flame sensor assembly | RepairClinic, SupplyHouse |
| Condensate drain kit | SupplyHouse |
| Gas pressure test kit (manometer) | Grainger |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If E001 persists after purging air and cleaning the igniter: a licensed plumber (gas-certified) should inspect the gas supply, pressure, and valve operation. Gas valve replacement on Navien units requires a licensed technician.