Skip to content
Industrial Error Code Fixes
Go back

Mitsubishi FR-E800 Fault E6 — Causes & Fix

⚡ Quick Answer

Mitsubishi FR-E800 E6 points to drive or parameter trouble. Check motor data, wiring, load, restart settings, and fault history before parts.

⚡ AT A GLANCEScroll down for full repair guide
What it meansMitsubishi FR-E800 E6 points to drive or parameter trouble. Check motor data, wiring, load, restart settings, and fault history before parts.
Most likely causeMost vfd faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededCooling fan
Repair intent

Need this fixed instead of diagnosed?

Mitsubishi FR-E800 E6 points to drive or parameter trouble. Check motor data, wiring, load, restart settings, and fault history before parts.

Likely parts to price

Price the common parts before you book service.

Cooling fan

Common VFD, drive, UPS, and cabinet overheating failure point.

Control keypad

Useful to price when faults involve display, keypad, or operator-panel behavior.

Fuses

Low-cost first check for power-stage and line-side faults.

Braking resistor

Price this on drive overvoltage, braking, or deceleration faults.

Mitsubishi FR-E800 Fault E6 — What It Means

Fault E6 on the Mitsubishi FR-E800 inverter indicates a brake transistor fault — the internal braking transistor (used to dissipate regenerative energy during deceleration) has failed or is operating outside normal parameters. The FR-E800 monitors the braking transistor duty cycle and temperature; if the transistor shorts or the braking resistor circuit is open, E6 trips to prevent a DC bus overvoltage condition.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Check for a shorted braking transistor — With power off, measure resistance between the P/+ terminal and PR terminal. Near-zero resistance in both directions indicates a shorted transistor.
  2. Inspect the braking resistor — Measure resistance across the braking resistor terminals (if external resistor installed). Open circuit = burned-out resistor. Check thermal fuse/switch on the resistor.
  3. Extend deceleration time — Increase Pr.8 (Deceleration Time) to reduce regenerative current per unit time. This is the first parameter fix to try before replacing hardware.
  4. Check wiring to braking resistor — Verify the resistor is connected between P/+ and PR terminals with correct wire gauge. Loose connections cause intermittent E6.
  5. Reset and test — After repair, cycle power and run a ramp-down cycle. Confirm E6 does not return.

Parts Often Needed

PartNotes
Braking resistorMatch to FR-E800 frame size and duty cycle requirement
FR-E800 inverter unitIf internal brake transistor has failed

Technician Tips

When diagnosing VFD faults, always check the drive’s fault history before resetting. Modern drives store the last 5-10 faults with the drive state at the time (running, accelerating, decelerating, stopped). An overcurrent fault that occurs only during acceleration points to incorrect motor data or mechanical binding. The same fault during deceleration suggests regeneration issues. A ground fault that clears after disconnecting the motor and returns when reconnected means the motor or cable insulation has failed.

Prevention: Schedule annual infrared scanning of drive cabinets. Loose power connections and failing capacitors produce heat long before they cause faults. A 5-minute scan can prevent hours of unplanned downtime.

Need Replacement Parts?

Before ordering, match the drive part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Internal braking transistor replacement requires drive disassembly and component-level repair. Mitsubishi authorized service handles transistor-level repairs for FR-E800 units.


Need a professional? Compare Industrial repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Mitsubishi FR-A800 Fault E7 — CPU Error Causes & Fix
Next Post
Mitsubishi FR Series VFD Fault E6 — Causes & Fix