Temperature sensor
Common error-code part. Confirm resistance and connector style.
LG mini-split CH26 error code means a current transformer (CT) sensor fault on the outdoor unit. Learn causes, diagnostic steps, and how to fix LG CH26.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.
Stock a year of filters so the airflow fault does not come back after the fix.
Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.
Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.
Pre-charged DIY ductless mini-split kits (9k to 36k BTU, single and multi-zone) with line set included. Price a whole-unit swap before paying for a compressor or board repair.
LG mini-split CH26 error code means a current transformer (CT) sensor fault on the outdoor unit. Learn causes, diagnostic steps, and how to fix LG CH26.
Error Code CH26 on LG mini-split and multi-zone systems indicates a current transformer (CT) sensor fault on the outdoor unit. The CT sensor monitors the compressor current draw and is critical for inverter compressor protection. When the sensor fails or reads outside its expected range, CH26 is triggered.
The CT (current transformer) sensor is a small toroidal coil that clamps around the compressor supply wire. It measures compressor current without direct electrical contact. The outdoor PCB reads this signal to protect the compressor from overcurrent and to control inverter frequency.
| Cause | Likelihood |
|---|---|
| CT sensor failed or disconnected | Very High |
| CT sensor wiring harness loose or broken | High |
| Outdoor PCB analog input failure | Medium |
| CT sensor mounted incorrectly (not around wire) | Medium |
| Actual compressor overcurrent (compressor fault) | Low |
Step 1 — Locate the CT sensor
Step 2 — Check the connector
Step 3 — Measure CT sensor output
Step 4 — Check wiring
Step 5 — Verify compressor operation
| Part | Notes |
|---|---|
| CT sensor (current transformer) | LG OEM part — match model number |
| Outdoor PCB | Only replace after confirming sensor and wiring are good |
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Note: LG CH26 is sometimes confused with CH25 (compressor overcurrent). CH25 means the compressor actually drew too much current; CH26 means the measurement circuit itself has failed. The repair procedures are different — CH25 leads to the compressor, CH26 leads to the sensor.