Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Goodman GSX13 guide for AC flash codes, pressure-switch trips, contactor faults, capacitor checks, fan problems, and control-board calls.
Goodman GSX13 guide for AC flash codes, pressure-switch trips, contactor faults, capacitor checks, fan problems, and control-board calls.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Goodman GSX13 is a 13 SEER single-stage residential central air conditioner using R-410A refrigerant. It is one of Goodman’s most widely installed entry-level units and uses a standard contactor-based control system. Fault codes are reported by a diagnostic LED on the outdoor control board — the same LED-based flash code system used across Goodman’s Comfort and Performance series. The GSX13 does not have a communicating control system.
| Flash Sequence | Fault |
|---|---|
| 1 flash | Normal / standby |
| 2 flashes | High-pressure switch open |
| 3 flashes | Low-pressure switch open |
| 4 flashes | Open circuit in compressor protection (overload or internal protection) |
| 5 flashes | Outdoor control board fault |
| 6 flashes | Outdoor ambient thermistor fault |
| 7 flashes | Discharge thermistor fault |
| Rapid flash | Low voltage — check transformer |
| Part | Notes |
|---|---|
| Dual run capacitor | Single most common GSX13 failure |
| Contactor | Check for pitting; replace if contacts are burned |
| Control board | For Code 5; check fuse first (usually 5A) |
| Run capacitor (fan only) | Some GSX13 boards use separate fan capacitor |
| High-pressure switch | For persistent Code 2 after coil service |
| Low-pressure switch | For persistent Code 3 with correct charge |
Goodman furnaces use a simple LED flash system on the control board. The diagnostic LED is usually visible through the blower compartment window. Count the flashes between pauses — that’s your error code. One flash = normal operation. Two flashes = pressure switch fault. Three flashes = limit switch. Four flashes = flame sensor. Goodman flame sensors are notorious for carbon buildup — cleaning with emery cloth every 2-3 years prevents most lockout calls. The control board on GMS8 and GMSS9 models is particularly sensitive to voltage fluctuations — if you see multiple different codes, check the transformer output (should be 24VAC ±10%).
Prevention: Install a whole-house surge protector on the furnace circuit to prevent board damage from power spikes.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Refrigerant work requires EPA 608 certification. If the GSX13 compressor is buzzing but not starting after capacitor replacement, the compressor may need a hard-start kit (potential relay + start capacitor) or may be mechanically seized. A technician with manifold gauges and a clamp meter is needed to distinguish between a slugged compressor and a failed one.