Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Troubleshoot Goodman 2 flashes on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Goodman 2 flashes on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Two flashes on a Goodman furnace LED means system lockout — the furnace control board has attempted ignition the maximum number of times (typically 3 retries) without success and has locked out to prevent unburned gas buildup. The board holds this fault until manually reset. This is a catch-all lockout: the root cause could be in any part of the ignition sequence — igniter, flame sensor, gas pressure, or pressure switch. The 2-flash code tells you the furnace gave up; the diagnostic work starts from there.
| Part | Notes |
|---|---|
| Hot surface igniter (Goodman B1401015S) | Common Goodman igniter; verify part number for your model |
| Flame sensor | Universal silicon nitride sensor fits most Goodman units |
| Pressure switch | Check water column rating on the old switch before ordering |
Goodman furnaces use a simple LED flash system on the control board. The diagnostic LED is usually visible through the blower compartment window. Count the flashes between pauses — that’s your error code. One flash = normal operation. Two flashes = pressure switch fault. Three flashes = limit switch. Four flashes = flame sensor. Goodman flame sensors are notorious for carbon buildup — cleaning with emery cloth every 2-3 years prevents most lockout calls. The control board on GMS8 and GMSS9 models is particularly sensitive to voltage fluctuations — if you see multiple different codes, check the transformer output (should be 24VAC ±10%).
Prevention: Install a whole-house surge protector on the furnace circuit to prevent board damage from power spikes.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the igniter tests good, flame sensor is clean, and draft system checks out, but lockout keeps returning, a combustion analysis and gas valve test requires a licensed tech with the right instruments.