Skip to content
Industrial Error Code Fixes
Go back

Goodman Furnace Error Codes — All Flash Codes Explained

⚡ Quick Answer

Use this Goodman Furnace Error Codes - All Flash Codes Explained reference to match the code with likely causes, service checks, and repair decisions.

⚡ AT A GLANCEScroll down for full repair guide
What it meansUse this Goodman Furnace Error Codes - All Flash Codes Explained reference to match the code with likely causes, service checks, and repair decisions.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Use this Goodman Furnace Error Codes - All Flash Codes Explained reference to match the code with likely causes, service checks, and repair decisions.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Goodman Furnace Error Codes — Quick Reference

Goodman furnaces signal faults through a flashing LED on the control board. Remove the lower access panel and count the repeating blink sequence. One long flash followed by shorter flashes indicates a two-digit code on newer boards; older boards use a simple count. Goodman shares its control board platform with Amana — the codes are identical across both brands.

CodeMeaningQuick Fix
1 flashLockout — retries exceededManual reset; check igniter and gas
2 flashesPressure switch stuck openCheck inducer, hose, drain trap
3 flashesPressure switch stuck closedInspect pressure switch hose routing
4 flashesOpen high-limit deviceReplace filter; check airflow
5 flashesFlame sensed with no call for heatGas valve may be leaking
6 flashes115V AC power reversed / bad groundCheck polarity at furnace disconnect
7 flashesGas valve energized without callGas valve or board fault
8 flashesLow flame sensor signalClean flame sensor rod
9 flashesIgniter circuit faultCheck igniter continuity; replace if open
ContinuousNormal operation (no fault)—
Slow flashStandby / waiting for callNormal
E1Communication fault (some models)Check thermostat wiring
EE2EEPROM memory faultReplace control board

Technician Tips

Goodman furnaces use a simple LED flash system on the control board. The diagnostic LED is usually visible through the blower compartment window. Count the flashes between pauses — that’s your error code. One flash = normal operation. Two flashes = pressure switch fault. Three flashes = limit switch. Four flashes = flame sensor. Goodman flame sensors are notorious for carbon buildup — cleaning with emery cloth every 2-3 years prevents most lockout calls. The control board on GMS8 and GMSS9 models is particularly sensitive to voltage fluctuations — if you see multiple different codes, check the transformer output (should be 24VAC ±10%).

Prevention: Install a whole-house surge protector on the furnace circuit to prevent board damage from power spikes.

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

Most Common Codes

1 Flash: Ignition Lockout

The furnace tried to light multiple times and gave up. Start with the flame sensor — a dirty rod is the #1 cause. Remove the sensor (single screw), rub the metal rod with 400-grit sandpaper or steel wool, and reinstall. If that doesn’t work, check the hot-surface igniter for cracks and verify the gas valve opens when the thermostat calls for heat.

2 Flashes: Pressure Switch Stuck Open

The draft inducer motor ran but the pressure switch didn’t see enough negative pressure to close. Check: (1) the rubber pressure switch hose for cracks, (2) the condensate drain trap for blockage on 90%+ models, (3) the inducer wheel for debris. A plugged secondary heat exchanger on high-efficiency models is also common.

4 Flashes: High Limit Open

The heat exchanger overheated and tripped the limit switch. Overwhelmingly caused by a clogged air filter. Replace the filter and allow the furnace to cool before resetting. If the limit trips again with a clean filter, check for blocked supply or return registers and verify the blower wheel isn’t clogged with debris.

5 Flashes: Flame Sensed — No Call for Heat

The flame sensor is detecting a signal even when the thermostat isn’t calling for heat. This usually means a leaking gas valve (allowing gas to seep and ignite on the hot surface of the heat exchanger) or a shorted flame sensor wire. This is a safety issue — shut off the gas supply and call a technician.

6 Flashes: Reversed Polarity / Bad Ground

Goodman furnaces are polarity-sensitive. The hot and neutral wires at the furnace disconnect or outlet must be wired correctly. Swap the two leads at the disconnect if needed. Also verify the unit has a proper earth ground — a missing ground is a common cause of nuisance lockouts.

8 Flashes: Low Flame Sensor Signal

The burner lit, but the microamp signal from the flame sensor is too low for reliable flame proving. Clean the sensor rod first. If cleaning doesn’t raise the signal above ~1.5 µA, the sensor rod may be cracked or positioned incorrectly in the burner flame.

When to Call a Pro

A 5-flash (flame sensed with no call) or 7-flash (gas valve energized unexpectedly) code indicates a potentially dangerous condition — gas valve failure or control board malfunction. Turn off the gas supply and contact a licensed technician before attempting further operation.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Goodman Furnace E2 Flame Sense Fault
Next Post