Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Diagnose Goodman Furnace EE2 Error Code - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.
Stock a year of filters so the airflow fault does not come back after the fix.
Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.
Limit switches, sequencers, blower motors, and control boards for Nordyne, Intertherm, Miller, and Coleman furnaces.
Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.
Diagnose Goodman Furnace EE2 Error Code - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
The Goodman EE2 error code appears on the communicating thermostat or control board display of newer Goodman furnaces using the ComfortNet or similar communicating control system. EE2 indicates a communication error — the furnace control board has lost communication with the system (typically the thermostat or the communicating system bus). Unlike the traditional blink codes, EE-series codes appear on digital displays and indicate a system-level control communication problem rather than a mechanical fault.
| Part | Notes |
|---|---|
| Communicating thermostat | Replace when thermostat communication circuit has failed |
| Furnace control board | Replace when board communication circuit fails and all wiring tests good |
| Low-voltage wiring (18/5 or 18/8) | Replace if wire continuity test shows any open conductors |
Goodman furnaces use a simple LED flash system on the control board. The diagnostic LED is usually visible through the blower compartment window. Count the flashes between pauses — that’s your error code. One flash = normal operation. Two flashes = pressure switch fault. Three flashes = limit switch. Four flashes = flame sensor. Goodman flame sensors are notorious for carbon buildup — cleaning with emery cloth every 2-3 years prevents most lockout calls. The control board on GMS8 and GMSS9 models is particularly sensitive to voltage fluctuations — if you see multiple different codes, check the transformer output (should be 24VAC ±10%).
Prevention: Install a whole-house surge protector on the furnace circuit to prevent board damage from power spikes.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If EE2 persists after replacing the thermostat and all wiring tests good, the furnace control board’s communication circuit has failed. Board replacement on newer communicating Goodman systems requires verifying firmware compatibility between the new board and the existing thermostat.