Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Goodman EE2 guide for communicating HVAC faults, wiring, power surges, 24VAC transformers, thermostat compatibility, and board checks.
Goodman EE2 guide for communicating HVAC faults, wiring, power surges, 24VAC transformers, thermostat compatibility, and board checks.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Goodman EE2 error code signals a control board communication fault — the system’s main control board cannot reliably exchange data with another module in the system, or the board itself has lost its internal operating state.
EE2 shows up on Goodman communicating systems where the outdoor unit, indoor unit, and thermostat share a data bus rather than simple 24VAC control signals. If that communication link breaks for any reason, the system throws EE2 and shuts down. The same control board platform appears in Amana and some Coleman products, so EE2 applies across those brands as well.
The error code has been trending on r/hvacadvice as more Goodman communicating systems age into their first major service cycle. Most threads resolve with one of three repairs: re-seating communication wiring, clearing a fault after a power surge, or replacing the control board. Homeowners who replace the board without confirming the wiring is correct often find the new board throws EE2 as well.
Reset the system completely. Turn off the thermostat, then turn off both the indoor and outdoor breakers. Wait 5 minutes. Restore power to the indoor unit first, then the outdoor, then turn on the thermostat. Many EE2 faults from momentary surges or glitches clear with a clean power cycle.
Inspect all communication wire connections. Find the communication terminal block on the indoor control board and the outdoor unit. Confirm each wire is fully seated under its terminal screw. Look for any wire that pulled out or has a damaged connector. Also check the thermostat base — a slightly loose wire there can produce intermittent EE2.
Verify wiring against the installation diagram. On communicating Goodman systems, the communication wires must land on specific terminals (often labeled A, B, C, or by color). Confirm the color-to-terminal assignment matches the installation manual, not a generic HVAC wiring reference.
Check the 24VAC transformer output. Measure transformer secondary voltage under load. It should read 24–28VAC. Below 22VAC under load suggests a weak or failing transformer that may be causing communication voltage to drop below the board’s threshold.
Inspect the control board for physical damage. Look for burn marks, swollen capacitors, cracked solder joints, or moisture residue on the board. Any visible damage points to board replacement.
Test with a known-good communicating thermostat. If you have access to a compatible replacement stat, swap it in temporarily. If EE2 clears with the test stat, the original thermostat is the failure point.
Confirm which board is at fault. Some Goodman communicating systems will display which module is failing on the diagnostic LED pattern or the thermostat screen. A fault pointing specifically to the outdoor board, indoor board, or thermostat narrows the replacement to one component.
Power surge or glitch — A full power cycle (as described in step 1) clears this in many cases. If the system runs after a clean reset and EE2 does not return, no additional repair is needed. Watch for recurrence over the next week.
Communication wiring fault — Re-seat all connections at every termination point. Clip back and re-strip any wire end that looks oxidized or has a poor crimp. Confirm terminal screw torque. On longer runs, check for a staple or conduit fitting that may have damaged the cable.
Weak transformer — Replace the 24VAC transformer. These are universal parts and cost $15–$30. Match the VA rating on the original.
Thermostat incompatibility or firmware — Install only Goodman-compatible communicating thermostats listed in the system’s installation manual. If using an approved stat, check the manufacturer’s website for a firmware update.
Failed control board — If wiring is confirmed correct and EE2 persists, replace the control board. Source the exact board for your Goodman model — Amana-branded and Coleman-branded counterparts may use the same part number. Boards typically run $80–$200. Photograph all existing wiring before removing the old board.
Call a licensed HVAC technician if the system reset and wiring inspection did not clear EE2, or if you confirmed a board failure but are not certain which board in the system failed. Replacing the wrong board wastes money and leaves the system down. A technician with a Goodman communicating system diagnostic tool can pull fault history and identify the failed component directly, saving the cost of a misdiagnosed repair.
EE2 is a control board communication fault. The main control board cannot reliably exchange data with another module in the system, or the board itself has lost its internal operating state, so the system shuts down.
Yes. Amana and some Coleman products share the same Goodman control board platform, so EE2 shows up across those brands as well.
Often yes. Turn off the thermostat, turn off both the indoor and outdoor breakers, wait 5 minutes, then restore power to the indoor unit first, then the outdoor unit, then the thermostat. Many EE2 faults from momentary surges or glitches clear with this reset.
Replace the control board only after confirming the wiring is correct and the 24VAC transformer output is within 24-28VAC under load. Replacing a board without confirming wiring first often results in the new board throwing EE2 as well.