Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
What Goodman 9 flash means, why reversed line/load power causes it, and how to fix the wiring safely.
What Goodman 9 flash means, why reversed line/load power causes it, and how to fix the wiring safely.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Nine flashes on a Goodman furnace diagnostic LED indicates reversed line and load power — the hot (L1) and neutral (L2) conductors supplying the furnace are swapped at the disconnect or power inlet. The furnace control board detects this polarity reversal through the flame sensing circuit and shuts the unit down. The furnace will not fire until polarity is corrected because a reversed neutral can create a shock hazard and false flame signals.
| Part | Notes |
|---|---|
| Outlet polarity tester | Inexpensive tool for quickly diagnosing reversed outlets |
| Wire nuts / terminals | For re-terminating corrected wiring connections |
| Furnace control board | Only if board was damaged by sustained polarity reversal (rare) |
Goodman furnaces use a simple LED flash system on the control board. The diagnostic LED is usually visible through the blower compartment window. Count the flashes between pauses — that’s your error code. One flash = normal operation. Two flashes = pressure switch fault. Three flashes = limit switch. Four flashes = flame sensor. Goodman flame sensors are notorious for carbon buildup — cleaning with emery cloth every 2-3 years prevents most lockout calls. The control board on GMS8 and GMSS9 models is particularly sensitive to voltage fluctuations — if you see multiple different codes, check the transformer output (should be 24VAC ±10%).
Prevention: Install a whole-house surge protector on the furnace circuit to prevent board damage from power spikes.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If you are not comfortable working inside an electrical panel or disconnect, call a licensed electrician. Reversed polarity at the panel is a shock hazard and should be corrected by someone qualified to work on live electrical systems. Once polarity is confirmed correct, the HVAC system should require no further repair.