Igniter
Price the ignition part only after confirming the model number and connector.
Goodman 7-flash guide for ignition lockout, gas supply checks, igniter and flame-sensor testing, rollout safety, and reset limits.
Goodman 7-flash guide for ignition lockout, gas supply checks, igniter and flame-sensor testing, rollout safety, and reset limits.
Likely parts to price
Price the ignition part only after confirming the model number and connector.
Common lockout part on gas heat and burner systems.
Relevant for pilot-safety and older gas appliance faults.
What it means: Seven flashes on a Goodman furnace indicates a gas heating lockout — the control board attempted ignition three consecutive times, failed to confirm flame each time, and locked out. During each ignition trial, the board energizes the hot surface igniter, waits for it to reach ignition temperature, opens the gas valve, then monitors the flame sensor for a microamp signal confirming a live flame. If the flame sensor does not respond within the trial period (typically 4–7 seconds after valve opens), the board closes the gas valve and logs a failed attempt. After three failures, it locks out with 7 flashes. Power must be cycled or the lockout timer (typically 60 minutes) must expire before another attempt.
Flame sensor cleaning resolves this fault roughly 60% of the time. Do it first, it costs nothing. If cleaning doesn’t hold, replace the sensor ($15–25).
If the igniter is weak (visibly dim red rather than bright orange-white), replace it. Goodman/Amana furnaces commonly use a Norton/Saint-Gobain silicon nitride igniter. Order by furnace model number for correct fit.
If both sensor and igniter check out and gas is flowing: the control board gas valve relay may have failed. Measure 24V AC at the gas valve terminals during ignition trial. If voltage is present but valve doesn’t open (no click, no gas), replace the valve. If no voltage is reaching the valve, replace the control board.
| Part | Where to Buy |
|---|---|
| Flame sensor | RepairClinic |
| Hot surface igniter | RepairClinic, SupplyHouse |
| Gas valve | SupplyHouse, Grainger |
| Control board | RepairClinic, Grainger |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Flame sensor cleaning and igniter replacement are appropriate DIY repairs. Gas valve replacement and gas pressure adjustment require a licensed HVAC technician. If the board is involved, a tech can perform a faster diagnosis using a service analyzer.