Carrier Infinity 24ACC6 Error Codes

⚡ Quick Answer

Carrier Infinity 24ACC6 guide for pressure trips, thermistors, compressor protection, discharge sensors, communication faults, and board checks.

⚡ AT A GLANCEScroll down for full repair guide
What it meansCarrier Infinity 24ACC6 guide for pressure trips, thermistors, compressor protection, discharge sensors, communication faults, and board checks.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Carrier Infinity 24ACC6 guide for pressure trips, thermistors, compressor protection, discharge sensors, communication faults, and board checks.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Carrier Infinity 24ACC6 Error Codes — What They Mean

The Carrier Infinity 24ACC6 is a high-efficiency single-stage central air conditioner designed to operate within Carrier’s Infinity communicating system. It uses a two-speed or variable-speed blower paired with an Infinity touch thermostat and communicates faults through both the thermostat display and a diagnostic LED on the outdoor control board. Flash codes appear when the unit is in standalone (non-communicating) mode; alphanumeric codes appear on the Infinity thermostat in full communicating mode.

Jump to Fix

Carrier 24ACC6 Error Code Reference

Code / FlashMeaning
2 flashesHigh-pressure switch open
3 flashesLow-pressure switch open
4 flashesCompressor protection active
5 flashesOutdoor control board fault
6 flashesOutdoor ambient temperature sensor fault
7 flashesDischarge line temperature sensor fault
8 flashesCommunication bus fault (Infinity link)
11 flashesThermistor fault — outdoor coil sensor
Thermostat: 174High-pressure trip
Thermostat: 175Low-pressure trip
Thermostat: 178Compressor communication fault
Thermostat: 179Outdoor fan fault

Common Causes by Code

Step-by-Step Fix

  1. Check the thermostat display first — In communicating mode, the Infinity touch thermostat shows alphanumeric fault codes directly. Navigate to System > Diagnostics to view all active and historical alerts.
  2. For Code 2 / high pressure — Turn the unit off at the thermostat. Inspect the condenser coil for fouling — cottonwood, grass clippings, and pet hair accumulate along the coil base. Flush from inside-out with a garden hose. Confirm the condenser fan is drawing air upward.
  3. For Code 3 / low pressure — Connect manifold gauges (R-410A). Suction pressure should be 100–115 PSI at 70°F ambient. Low charge requires finding the leak before adding refrigerant. Use an electronic leak detector at service ports, coil connections, and line set fittings.
  4. For Code 8 / communication — Check the control wire for damage (staples through the wire are a common installation defect). Verify the wire is connected to the correct terminals on all three components. Test voltage at the board.
  5. Clear faults — Power cycle the outdoor disconnect, wait 30 seconds, and restore power. Monitor for fault recurrence within the first cooling cycle.

Parts Often Needed

PartNotes
Run capacitorDual run capacitor for compressor and fan motor
ContactorCheck for pitted or welded contacts
Low-pressure switchReplace if Code 3 persists with correct charge
Outdoor coil thermistorFor Code 11; inexpensive OEM part
Infinity control boardFor persistent Code 5 or communication faults
Condenser fan motorConfirm correct rotation before condemning

Technician Tips

Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.

Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.

Parts note: For Infinity 24ACC6 faults, match parts to the outdoor unit and Infinity communication path: sensors, pressure switches, control boards, communication wire, and fan components.

Need Replacement Parts?

Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Refrigerant work requires EPA 608 certification. Infinity system communication faults can require Carrier Service Advisor software (ICP/SA) to perform advanced diagnostics — this is a dealer-level tool not available to the general public. If the Infinity thermostat is showing fault codes not covered in the standard code list, contact a Carrier factory-authorized dealer.


Need a professional? Compare HVAC repair options before replacing parts.