Skip to content
Industrial Error Code Fixes
Go back

Carrier 44 Error Code - Open Igniter Circuit

⚡ Quick Answer

Carrier code 44 open-igniter guide for cracked hot-surface igniters, loose harnesses, failed board relays, and wrong replacement igniters.

⚡ AT A GLANCEScroll down for full repair guide
What it meansCarrier code 44 open-igniter guide for cracked hot-surface igniters, loose harnesses, failed board relays, and wrong replacement igniters.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededIgniter
Repair intent

Need this fixed instead of diagnosed?

Carrier code 44 open-igniter guide for cracked hot-surface igniters, loose harnesses, failed board relays, and wrong replacement igniters.

Likely parts to price

Price the common parts before you book service.

Igniter

Price the ignition part only after confirming the model number and connector.

Flame sensor

Common lockout part on gas heat and burner systems.

Thermocouple

Relevant for pilot-safety and older gas appliance faults.

Carrier 44 Error Code — What It Means

Carrier error code 44 indicates an open igniter circuit. The furnace control board detected that the igniter is not drawing the expected current when energized, which means the igniter is either broken, disconnected, or the circuit supplying it has failed. The furnace will lock out on this fault to prevent unlit gas from accumulating.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Power down the furnace — Turn the power switch off and set the thermostat to OFF before opening the cabinet.
  2. Locate and visually inspect the igniter — The hot surface igniter is typically a silicon carbide or silicon nitride rod mounted near the burner assembly. Look for visible cracks, fractures, or burn marks.
  3. Measure igniter resistance — Use a multimeter set to ohms. Disconnect the igniter harness and measure across the igniter terminals. Silicon carbide igniters should read 40–90 Ω at room temperature; silicon nitride should read 15–75 Ω. An open reading (OL) confirms a failed igniter.
  4. Check the igniter wiring harness — Inspect the plug at both the igniter and the control board. Reseat loose connectors and look for melted or damaged wire insulation.
  5. Test voltage at the igniter connector — With power restored and a call for heat, measure AC voltage at the igniter harness during the igniter pre-heat sequence. You should see approximately 120V. No voltage points to the control board relay.
  6. Replace the igniter — Use a Carrier-compatible igniter for your model. Part numbers vary by series; cross-reference with the furnace model tag.
  7. Reset the system — Restore power, set the thermostat to Heat, and verify the igniter glows and the burners light normally. Clear any lockout by cycling the power switch.

Parts Often Needed

PartNotes
Hot surface igniterMatch to furnace model; silicon nitride is more durable than silicon carbide
Igniter wiring harnessReplace if insulation is melted or connector pins are corroded
Furnace control boardOnly if relay confirmed open under load testing

Technician Tips

Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.

Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.

Common replacement parts for Carrier systems:

Need Replacement Parts?

Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If voltage is confirmed at the igniter connector but the board still throws a 44 fault, or if you suspect a gas valve issue is masking the fault, call a licensed HVAC technician. Gas train diagnostics require proper combustion testing equipment.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Carrier 42 Error Code - Inducer Motor Fault
Next Post
Carrier 45 Error Code - IFC Control Board Fault