What it means: Code 43 is a rollout switch lockout. The rollout switch (also called a flame rollout limit) is a manual-reset thermal fuse mounted on the burner box. It trips when it detects flame escaping out of the burner compartment instead of staying in the heat exchanger. Normal flame should be contained inside the heat exchanger — rollout means something is forcing combustion gases backward. Code 43 requires a manual reset of the rollout switch itself; cycling power to the furnace will not clear it.
If the flue is blocked: clear the obstruction and test. If the inducer is weak: check inducer motor amperage and RPM against spec — replace if below rating.
If the heat exchanger is cracked, the furnace must be taken out of service. A cracked heat exchanger is not a DIY repair — the entire heat exchanger or furnace needs replacement. This is a safety-critical failure.
If no structural fault is found: check gas manifold pressure with a manometer. For natural gas, manifold pressure should typically be 3.5 inches W.C. at the burner. Adjust the gas valve regulator if pressure is out of spec.
Once the root cause is corrected, locate the rollout switch (typically a disc-shaped device with a red reset button mounted on the burner box). Press the reset button firmly. Restore power and run a test cycle.
| Part | Where to Buy |
|---|---|
| Rollout switch / limit switch | RepairClinic, SupplyHouse |
| Inducer motor assembly | RepairClinic, Grainger |
| Gas valve | SupplyHouse, Grainger |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Any Code 43 with suspected heat exchanger failure requires a licensed HVAC technician immediately. A cracked heat exchanger is a carbon monoxide hazard. Do not operate the furnace until the heat exchanger is inspected and cleared. Gas valve adjustments also require proper test equipment and licensing in most jurisdictions.