Skip to content
Industrial Error Code Fixes
Go back

Carrier 43 Error Code — Rollout Switch Open Fix

⚡ Quick Answer

Carrier 43 rollout-switch guide for flame rollout, blocked flues, inducer draft, gas pressure, heat exchanger risk, and manual resets.

⚡ AT A GLANCEScroll down for full repair guide
What it meansCarrier 43 rollout-switch guide for flame rollout, blocked flues, inducer draft, gas pressure, heat exchanger risk, and manual resets.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Carrier 43 rollout-switch guide for flame rollout, blocked flues, inducer draft, gas pressure, heat exchanger risk, and manual resets.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Error Code: Carrier 43

What it means: Code 43 is a rollout switch lockout. The rollout switch (also called a flame rollout limit) is a manual-reset thermal fuse mounted on the burner box. It trips when it detects flame escaping out of the burner compartment instead of staying in the heat exchanger. Normal flame should be contained inside the heat exchanger — rollout means something is forcing combustion gases backward. Code 43 requires a manual reset of the rollout switch itself; cycling power to the furnace will not clear it.

Common Causes

Diagnosis Steps

  1. Do NOT reset the rollout switch until you identify the cause. Repeated resets without diagnosis is a CO safety risk.
  2. Visually inspect the burner compartment with the front panel removed. Look for soot deposits on the inside of the burner box — soot outside the normal burn zone indicates rollout has occurred.
  3. Start the inducer motor manually (using a jumper or test mode) and hold your hand near the burner area before ignition. You should feel strong draft pulling inward. Weak or reversed airflow points to a blocked flue or failed inducer.
  4. Inspect the flue pipe for blockages: disconnected sections, bird nests, ice (in cold climates), or excess condensate backup.
  5. Perform a heat exchanger inspection with a camera or mirror. Cracks often appear at the clam-shell seams. If in doubt, perform a combustion analysis or call for a pressure test.

Fix

If the flue is blocked: clear the obstruction and test. If the inducer is weak: check inducer motor amperage and RPM against spec — replace if below rating.

If the heat exchanger is cracked, the furnace must be taken out of service. A cracked heat exchanger is not a DIY repair — the entire heat exchanger or furnace needs replacement. This is a safety-critical failure.

If no structural fault is found: check gas manifold pressure with a manometer. For natural gas, manifold pressure should typically be 3.5 inches W.C. at the burner. Adjust the gas valve regulator if pressure is out of spec.

Once the root cause is corrected, locate the rollout switch (typically a disc-shaped device with a red reset button mounted on the burner box). Press the reset button firmly. Restore power and run a test cycle.

Parts

PartWhere to Buy
Rollout switch / limit switchRepairClinic, SupplyHouse
Inducer motor assemblyRepairClinic, Grainger
Gas valveSupplyHouse, Grainger

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Technician

Any Code 43 with suspected heat exchanger failure requires a licensed HVAC technician immediately. A cracked heat exchanger is a carbon monoxide hazard. Do not operate the furnace until the heat exchanger is inspected and cleared. Gas valve adjustments also require proper test equipment and licensing in most jurisdictions.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Lennox Error Code 412 Limit Switch Fault
Next Post
Lennox Error Code 441 — Limit Device Fault