Skip to content
Industrial Error Code Fixes
Go back

Carrier 33 Error Code - Limit Switch Open

⚡ Quick Answer

Carrier 33 means the furnace limit circuit opened during heat. Check airflow, filter, blower capacitor, rollout switches, flue, and heat exchanger.

⚡ AT A GLANCEScroll down for full repair guide
What it meansCarrier 33 means the furnace limit circuit opened during heat. Check airflow, filter, blower capacitor, rollout switches, flue, and heat exchanger.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Carrier 33 means the furnace limit circuit opened during heat. Check airflow, filter, blower capacitor, rollout switches, flue, and heat exchanger.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Carrier 33 Error Code — What It Means

Carrier furnace fault code 33 means the limit device is open — the high-limit or rollout switch has tripped and cut off gas to prevent overheating. The control board flashes 3 long, 3 short. This is a safety lockout: the furnace detected that heat exchanger or plenum temperatures exceeded safe limits, or combustion gases rolled out of the heat exchanger. The root cause is almost always an airflow or combustion problem, not a failed limit switch itself.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Check and replace the air filter — Pull the filter and inspect it. If it’s grey or clogged, swap it. A $5 filter causes 40% of limit lockouts. Restart after replacement.
  2. Verify blower operation — With the furnace running, confirm the blower starts within 30–60 seconds of ignition. If it doesn’t spin or spins slowly, test the run capacitor with a capacitor meter. Replace if it reads more than 10% below rated capacitance.
  3. Inspect supply and return vents — Walk the house and open all closed registers. Check that furniture or boxes aren’t blocking return air grilles. Blocked returns are a fast path to limit trips.
  4. Locate and reset the rollout switch — The rollout switch sits near the burners. It has a red reset button. Press it firmly. If it trips again within one cycle, stop — you likely have a cracked heat exchanger and need a tech.
  5. Reset the system — Cut power at the furnace switch for 30 seconds, then restore. If code 33 returns within the first heating cycle after fixing airflow, escalate to a heat exchanger inspection.

Parts Often Needed

PartNotes
High-limit switchTrips on temp; test with multimeter for continuity at room temp — should be closed
Rollout limit switchManual reset; if it trips repeatedly, the heat exchanger is the problem
Blower run capacitorMost common blower fix; costs $10–20 and takes 15 minutes
Air filter (MERV 8–11)Replace every 90 days minimum

Technician Tips

Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.

Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.

Common replacement parts for Carrier systems:

Need Replacement Parts?

Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If the rollout switch trips more than once after resetting, or if you find cracks or rust holes in the heat exchanger during inspection, stop using the furnace and call a tech. A cracked heat exchanger is a carbon monoxide hazard.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Carrier Heat Pump E1 Error Code — Causes & Fix
Next Post
Carrier 41 Error Code — Blower Motor Fault Fix