ATS faults cover source failure, transfer inhibit, position errors, motor faults, overcurrent, maintenance mode, and generator auto status.
ATS faults cover source failure, transfer inhibit, position errors, motor faults, overcurrent, maintenance mode, and generator auto status.
Likely parts to price
Common no-start cause. Match size, terminal layout, and cold-cranking requirements.
Low-cost maintenance part for start, misfire, and rough-run symptoms.
Useful first-price item for service intervals and restricted-airflow faults.
Price this for output-voltage faults after basic electrical checks.
Automatic transfer switches (ATS) monitor utility power and transfer loads to a generator when utility power fails. Major ATS brands include Generac (RTSY, RTSN series), Kohler (RDT, KCTS series), Asco (Series 300, 7000), and Russelectric. Faults appear on the ATS controller display and are often transmitted to the generator’s controller.
| Fault | Brand / Type | Meaning | Quick Fix |
|---|---|---|---|
| Source 1 Fail | All | Utility power has failed | Normal — ATS should transfer to generator |
| Source 2 Fail | All | Generator not available | Check generator; check ATS-to-gen wiring |
| Transfer Inhibit | All | Transfer blocked by external input | Check inhibit wiring |
| Time Delay Active | All | Transfer delay counting down | Normal — wait for delay to expire |
| Overcurrent | Asco, Russelectric | Load current exceeded ATS rating | Reduce load; check for faults |
| Motor Fault | Asco, Kohler | Transfer mechanism motor fault | Inspect motor; check contacts |
| Position Fault | All | ATS didn’t reach commanded position | Check mechanism; check contacts |
| Neutral Overlap | 3-pos ATS | In neutral position during transfer | Normal brief state |
| Generator Not In Auto | All | Generator controller not in AUTO mode | Set generator to AUTO |
| Maintenance Mode | All | ATS manually set to bypass | Return to AUTO after maintenance |
| Com Fault | Networked ATS | Communication to remote device lost | Check network wiring |
When utility power fails and the ATS calls for the generator, “Source 2 Fail” means the generator did not come online within the expected time or is not producing correct voltage. Check:
The ATS transfer mechanism (typically a solenoid-operated or motor-driven contactor) did not move to the commanded position within the timeout window. Check:
This is the simplest fault to fix — but also one of the most common reasons a generator fails to start during an actual power outage. After any maintenance on the generator, always verify the generator controller is returned to AUTO mode. The ATS will display this fault continuously when the generator is in manual or off mode.
The transfer inhibit input is a dry-contact input on the ATS that allows external systems to temporarily prevent transfer. Common sources of transfer inhibit signals include:
Check the inhibit wiring terminal on the ATS and verify no unintended inhibit signal is present.
| Display | Meaning |
|---|---|
| S1 FAIL | Source 1 (normal) power failure |
| S2 NOT AVL | Source 2 (emergency) not available |
| XFER INHIBIT | Transfer prevented by external signal |
| PWR SUPP FLT | ATS internal power supply fault |
| COM FAIL | Remote monitoring communication fault |
| MAINT BYPSS | Manual bypass mode active |
Before ordering, match the generator part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
ATS maintenance and repairs involve both utility-side and generator-side electrical hazards. Always have a qualified electrician perform any physical work inside an ATS enclosure — the utility-side terminals remain energized even when the generator is supplying the load.