WaterFurnace Series 7 geothermal heat pump error codes and fault diagnostics. IntelliZone2 fault codes, causes, and technician-level fixes.
WaterFurnace Series 7 geothermal heat pump error codes and fault diagnostics. IntelliZone2 fault codes, causes, and technician-level fixes.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
WaterFurnace Series 7 units use the Aurora Base Control (ABC) board with IntelliZone2 for monitoring and diagnostics. Fault codes display on the IntelliZone2 thermostat or Aurora Web Link. Faults are categorized as warnings (unit continues) or lockouts (unit shuts down).
| Code | Fault Description | Common Cause | Severity |
|---|---|---|---|
| LO | Low-pressure lockout | Low refrigerant, low loop flow | Lockout |
| HI | High-pressure lockout | Dirty coil, high loop temp, overcharge | Lockout |
| FP1 | Freeze protection 1 | Low loop EWT, low refrigerant | Lockout |
| FP2 | Freeze protection 2 | Low air coil temp | Lockout |
| HA | High amperage | Compressor overloading | Lockout |
| EE | EEPROM error | Control board fault | Lockout |
| CO | Communication fault | Wiring to IntelliZone2 | Warning |
| FT | Flow fault | Low loop GPM | Warning |
| RV | Reversing valve fault | Valve or solenoid issue | Lockout |
| LT | Low loop temp warning | EWT approaching freeze protection | Warning |
| HT | High discharge temp | Refrigerant issue | Lockout |
| CC | Compressor contactor fault | Contactor or wiring | Lockout |
Triggered when entering water temperature (EWT) drops near 32 degrees F. Check loop pump operation, loop pressure, and antifreeze concentration (should be 15-20% methanol or propylene glycol for protection to 15 degrees F).
Series 7 operates on R-410A. Low-side pressure below 40 psi triggers LO. Check loop flow rate (minimum 1.5 GPM/ton for closed loop), refrigerant charge, and TXV operation.
High loop entering water temperature or refrigerant overcharge causes HI. Measure EWT - should not exceed 90 degrees F for typical cooling season operation. Check water coil for scale buildup.
The Series 7 monitors loop flow via a differential pressure switch. Check loop pump rotation, purge air from loop, and verify loop pressure (15-30 psi static).
| Part | Notes |
|---|---|
| Aurora Base Control board | ABC - match to unit model and software version |
| IntelliZone2 thermostat | Communication interface for fault codes |
| Loop pump | Verify GPM meets unit minimum |
| TXV | Match refrigerant and tonnage |
| Reversing valve | Match unit model |
| Pressure transducer | Check calibration before replacing |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: WaterFurnace Series 7 has variable speed compressor (0-100% capacity). Always view IntelliZone2 diagnostics screen for current operating pressures and EWT/LWT before diagnosing refrigerant issues.