Trane XR13 guide for LED flash faults, high/low pressure trips, compressor protection, thermistors, charge loss, and anti-short-cycle delay.
Trane XR13 guide for LED flash faults, high/low pressure trips, compressor protection, thermistors, charge loss, and anti-short-cycle delay.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Trane XR13 is a 13 SEER single-stage central air conditioner in Trane’s value-line residential series. It uses R-410A refrigerant and a single-speed scroll compressor. Like most entry-level condensing units, the XR13 relies on a diagnostic LED on the control board to report faults via flash sequences rather than communicating through a smart thermostat. The LED is visible through the access panel on the outdoor unit.
| Flash Sequence | Fault |
|---|---|
| Continuous ON | Normal operation |
| 2 flashes | High-pressure switch open |
| 3 flashes | Low-pressure switch open |
| 4 flashes | Open circuit — compressor protection device |
| 5 flashes | Control board fault |
| 6 flashes | Outdoor thermistor fault |
| 7 flashes | Loss of charge (pressure switch) |
| 8 flashes | Anti-short cycle delay active |
| 9 flashes | Communication fault (if connected to ComfortLink thermostat) |
| Part | Notes |
|---|---|
| Dual run capacitor | Most common failure on XR13 outdoor units |
| Contactor | Replace if contacts are pitted or discolored |
| Condenser fan motor | Confirm rotation direction (counterclockwise from top) |
| High-pressure switch | Replace if Code 2 persists after coil cleaning |
| Low-pressure switch | Replace if Code 3 persists with correct charge |
| Control board | For Code 5; check fuse before replacing board |
For Trane heat pump and air-conditioner faults, confirm thermostat demand, outdoor board history, sensor resistance, airflow, coil condition, and refrigerant-pressure conditions before replacing controls or motors.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Any investigation of low-pressure or high-pressure faults that goes beyond visual inspection and switch testing requires refrigerant manifold gauges and EPA 608 certification. If the compressor hums but won’t start, test the capacitor first — a failed run capacitor is the most common cause of compressor no-start on XR13 units.