Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Trane 6-flash rollout guide for blocked flues, weak inducer motors, cracked heat exchangers, gas-valve issues, and manual-reset limits.
Trane 6-flash rollout guide for blocked flues, weak inducer motors, cracked heat exchangers, gas-valve issues, and manual-reset limits.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Six LED flashes on a Trane furnace control board indicates the rollout switch has tripped. The rollout switch is a thermal safety device mounted on or near the burner assembly. It opens if flame rolls out of the heat exchanger — typically caused by a blocked flue, a cracked heat exchanger, a restricted combustion air path, or an induced draft motor that can’t maintain proper draft. A tripped rollout switch is a serious safety event and should not be ignored or bypassed.
| Part | Notes |
|---|---|
| Rollout switch (manual reset) | Match the correct temperature rating for your model |
| Induced draft motor | Replace if running slow, noisy, or failing to start |
| Flue vent pipe section | Replace collapsed or damaged vent segments |
Trane furnaces typically flash error codes through the LED on the integrated furnace control (IFC) board. Code 11 (no previous code) is the startup default — if you see this with a no-heat call, check for power at the IFC. Code 12 means blower on after power-up — normal after a reset. Code 13 means limit switch fault — this is often a dirty filter or restricted return. Code 14 means ignition failure — check gas pressure before condemning the igniter. Trane uses silicon nitride igniters that last longer than standard carbides but are more fragile during handling.
Estimated repair time: Most Trane ignition faults take 30-45 minutes to diagnose and fix. Limit switch and blower motor issues run 1-2 hours.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
A tripped rollout switch that cannot be attributed to a blocked flue is a strong indicator of a cracked heat exchanger — a condition that poses carbon monoxide risk. Do not operate the furnace until a licensed technician performs a full heat exchanger inspection.