Troubleshoot Trane 5 flashes on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Trane 5 flashes on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Five flashes on a Trane furnace LED means the pressure switch is stuck open. The pressure switch is a safety device that confirms the induced draft blower is moving enough air to safely exhaust combustion gases. When the switch stays open, the control board sees no airflow confirmation and won’t allow ignition. This code appears immediately at startup, before the igniter even energizes. The switch itself is often fine — the more common culprits are blocked vents, a failing draft motor, or a condensate backup in the pressure switch tubing.
| Part | Notes |
|---|---|
| Pressure switch | Match the water column rating on the old switch (e.g., -0.65” WC) |
| Draft motor run capacitor | Cheap fix if motor hums but won’t start |
| Pressure switch hose (3/8” ID) | Cut to length; sells by the foot |
| Condensate trap | Replace if cracked or permanently clogged |
Trane furnaces typically flash error codes through the LED on the integrated furnace control (IFC) board. Code 11 (no previous code) is the startup default — if you see this with a no-heat call, check for power at the IFC. Code 12 means blower on after power-up — normal after a reset. Code 13 means limit switch fault — this is often a dirty filter or restricted return. Code 14 means ignition failure — check gas pressure before condemning the igniter. Trane uses silicon nitride igniters that last longer than standard carbides but are more fragile during handling.
Estimated repair time: Most Trane ignition faults take 30-45 minutes to diagnose and fix. Limit switch and blower motor issues run 1-2 hours.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the draft motor is confirmed running at speed and the vent pipes are clear, but the switch still won’t close, a tech should verify static pressure with a manometer before condemning the switch. An incorrectly rated replacement switch will fail in the same way.