Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Diagnose Tempstar Furnace E4 Error Code - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Diagnose Tempstar Furnace E4 Error Code - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
E4 on a Tempstar furnace signals an open limit circuit — the high-limit switch or rollout switch has tripped due to excessive heat. Tempstar is an ICP brand (same parent as Heil, Comfortmaker, and Carrier) and the control board logic is shared across these families. When the limit circuit opens, the board shuts off the gas valve immediately and flashes E4. The blower typically keeps running to cool the heat exchanger. Repeated E4 faults point to an airflow problem or a failing heat exchanger.
| Part | Notes |
|---|---|
| High-limit switch | Match the °F trip rating and mounting configuration |
| Rollout limit switch | Many are auto-reset; persistent trips require root-cause repair |
| Blower run capacitor | Match µF and VAC rating exactly |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the rollout switch trips repeatedly after resetting, have a technician check for a cracked heat exchanger before using the furnace — cracked exchangers are a carbon monoxide hazard and require heat exchanger or furnace replacement.