Cooling fan
Common VFD, drive, UPS, and cabinet overheating failure point.
Siemens Sinumerik 380500 guide for SINAMICS sub-faults, DRIVE-CLiQ cables, motor modules, encoder feedback, cooling, and fault buffers.
Siemens Sinumerik 380500 guide for SINAMICS sub-faults, DRIVE-CLiQ cables, motor modules, encoder feedback, cooling, and fault buffers.
Likely parts to price
Common VFD, drive, UPS, and cabinet overheating failure point.
Useful to price when faults involve display, keypad, or operator-panel behavior.
Low-cost first check for power-stage and line-side faults.
Price this on drive overvoltage, braking, or deceleration faults.
Siemens Sinumerik alarm 380500 (%1 is a group alarm for drive (SINAMICS/611D) faults detected via the DRIVE-CLiQ or PROFIBUS interface between the NCK and the drive system. The %1 parameter in the alarm text substitutes the specific drive component identifier (e.g., “SERVO_1” or “A1:S1.1”) and the sub-fault type. Alarm 380500 typically indicates that the Sinumerik NCK received a fault report from the connected SINAMICS S120 or 840D servo drive and shut down the affected axes. The actual root cause is in the drive’s own fault memory, not in the CNC alarm directly.
| Part | Notes |
|---|---|
| DRIVE-CLiQ cable | Replace if signal quality is degraded or cable is physically damaged |
| SINAMICS S120 motor module | Replace if hardware fault confirmed in drive diagnostics |
| Encoder cable (SMC to motor) | Replace if encoder fault is the confirmed sub-fault |
CNC alarms should always be diagnosed by reading the full alarm text, not just the number. Modern Fanuc, Haas, and Mazak controls provide detailed alarm descriptions — press the help key while viewing the alarm for diagnostic suggestions. The alarm history screen stores the last 50-100 alarms with timestamps; review this before clearing to identify patterns. A servo alarm (SV series on Fanuc) that appears only during rapid traverse points to a different cause than one that appears during cutting.
Prevention: Back up your CNC parameters monthly. Battery-backed memory faults are much easier to recover when you have a current parameter, ladder, offset, and macro backup. Replace control batteries on a planned maintenance schedule before voltage drops far enough to risk data loss.
Before ordering, match the machine-control part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Sinumerik 840D/840Dsl systems require Siemens commissioning software (Starter or SINAMICS Startdrive) to properly diagnose drive-level faults and re-commission servo parameters after a motor module replacement. This work is typically performed by a Siemens-certified service engineer.
Alarm 380500 is a group alarm showing that the Sinumerik control received a SINAMICS or 611D drive fault through the drive interface. The root cause is in the drive fault memory.
Open the drive diagnostics or fault buffer on the Sinumerik HMI and record the specific SINAMICS fault code, such as an F-code or A-code, before clearing the alarm.
Yes. A loose, damaged, or degraded DRIVE-CLiQ connection between the NCU, NX modules, and motor modules can trigger alarm 380500 with a communication sub-fault.
Call a Siemens-qualified service engineer when the fault buffer points to motor-module hardware, commissioning parameters, drive-level faults, or work that requires Starter or SINAMICS Startdrive.