Siemens G120 F01033 - Causes & Fix

3 min read
⚡ Quick Answer

F01033 means a reference parameter for unit conversion is invalid (often 0.0). Fix by correcting the scaling parameter in your drive setup.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Siemens G120 F01033 — What It Means

F01033 on a Siemens SINAMICS G120 drive means “Unit switchover: Reference parameter value invalid.” The drive has detected that a reference parameter used for unit conversion or scaling is invalid or improperly set. This is a configuration fault, not a hardware overcurrent or thermal fault. The most common trigger is that one of the required reference parameters is set to 0.0, which is not permitted for the conversion calculation. The fault typically appears after commissioning changes, parameter downloads, or when a unit changeover is made without updating all related reference values consistently.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Access the fault buffer in the drive using the operator panel (BOP-2 or IOP) or your PC with Startdrive to read fault F01033 and note any additional diagnostic data stored with the fault.
  2. Identify the reference parameter involved in the fault by reviewing the unit conversion and scaling settings in your parameter set, typically found in the technology or reference parameter group.
  3. Check for zero or invalid values in all reference parameters related to unit switchover, scaling, or engineering-unit conversion, and compare them to your commissioning documentation or machine specification.
  4. Correct the invalid parameter by entering the proper reference value from your commissioning data or machine manual, then save the corrected parameter set to the drive’s nonvolatile memory.
  5. Verify parameter consistency by reviewing the full parameter set for any other unit-conversion or scaling parameters that may have been affected by the same download or change event.
  6. Clear the fault using the operator panel, a digital input configured for fault reset, the control word from your controller, or by cycling power to the drive, depending on your system setup.
  7. Re-test the drive by running the motor under normal operating conditions and confirming that F01033 does not reappear, then monitor the fault buffer for any new diagnostic entries.

Parts Often Needed

PartNotes
Siemens Startdrive commissioning softwareAmazon | Required for advanced parameter editing and backup if your operator panel access is limited.
Siemens BOP-2 or IOP operator panelAmazon | Allows on-site fault reading and parameter adjustment if your existing panel is damaged or missing.

When to Call a Pro

Call a qualified Siemens drive technician or automation engineer if you do not have access to the original commissioning parameter file, if the fault persists after verifying and correcting all reference values, or if you are unfamiliar with navigating the G120 parameter structure. A professional with Startdrive experience can compare your current parameter set to a known-good baseline and identify hidden inconsistencies in the reference or unit-conversion configuration. Also seek expert help if the drive was part of a larger system integration and you do not have documentation for the scaling or engineering-unit setup.