⚡ Quick Answer

F01018 means the G120 drive's power-up was interrupted multiple times and it reverted to factory settings. Fix by checking supply power stability first.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Siemens F01018 — What It Means

Fault F01018 on a Siemens SINAMICS G120 indicates that the drive’s controller detected repeated interrupted boot attempts during startup. When this happens, the drive automatically reverts to factory settings as a fallback. The fault typically points to an unstable power supply during the power-up sequence, a corrupted parameter set, or an internal CPU issue preventing normal boot completion.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Fully power down the drive and disconnect all supply power, then wait for the DC bus to discharge completely before attempting any further action.
  2. Power the drive back on once only and observe whether F01018 reappears immediately or if the drive completes a normal boot cycle.
  3. Check incoming power supply stability by measuring line voltage during startup with a meter to confirm no sags or drops occur, and inspect all power and control terminals for loose, corroded, or intermittent connections.
  4. Read the fault buffer in the drive’s diagnostics menu to review the complete fault history and check for other startup-related errors that preceded F01018.
  5. Inspect and verify drive parameterization by reviewing commissioning data and startup parameters for invalid or corrupted values, or reload a known-good parameter set from backup.
  6. Test with a clean power cycle after correcting any supply or parameter issues, and monitor the drive through several full startup sequences to confirm stable operation.
  7. Replace or reprogram the control unit if F01018 persists after confirming stable supply power and valid parameters, since repeated boot interruption points to a control-side hardware failure rather than an external load problem.

Parts Often Needed

PartNotes
G120 Control Unit Module (CU)Amazon | Required if repeated boot failures persist after supply and parameter checks. Confirm your exact G120 model and CU variant before ordering.
Siemens parameter backup memory cardAmazon | Useful for restoring known-good parameter sets if corrupted commissioning data is suspected.

When to Call a Pro

Call a qualified Siemens technician or certified drive specialist if F01018 returns immediately after a clean power cycle and you have confirmed stable incoming power and valid parameterization. Repeated boot interruptions that survive basic supply and parameter troubleshooting usually indicate an internal control-unit fault requiring specialized diagnostic tools, firmware updates, or module replacement. If the drive is mission-critical or connected to expensive machinery, professional support will prevent extended downtime and avoid damage from trial-and-error parts swapping.