Rheem tankless temperature sensor
Part: RTG20009B
Sensor cited for RTGH secondary heat exchanger and outlet temperature faults.
Rheem RTGH-95DVLN guide for condensing tankless faults, secondary heat-exchanger issues, condensate problems, ignition failures, and sensor errors.
Rheem RTGH-95DVLN guide for condensing tankless faults, secondary heat-exchanger issues, condensate problems, ignition failures, and sensor errors.
Parts to price first
Part: RTG20009B
Sensor cited for RTGH secondary heat exchanger and outlet temperature faults.
Maintenance part for acidic condensate on condensing tankless installs.
Flush kit listed for scale-related codes 16, 29, and 33.
Part: AP15516-1
Fan assembly cited for code 61 after wiring and airflow checks.
Used when a gravity condensate drain is not possible.
Ignition part listed for code 11 after gas and vent checks.
The Rheem RTGH-95DVLN is Rheem’s flagship condensing tankless water heater, a natural gas indoor direct vent unit rated at 9.5 GPM maximum flow and up to 199,000 BTU/hr input. It’s a condensing unit, which means it has both a primary and secondary heat exchanger, a condensate drain system, and a flue gas temperature well below 120°F at the exhaust termination. When a fault occurs, the unit displays a two-digit error code on its front panel and stops firing. This guide covers every code the RTGH-95DVLN generates and how to resolve each one.
Error codes on the RTGH-95DVLN appear as two-digit numbers on the LED display on the unit’s front panel. When an error code is active, the unit shuts down and displays the code until either the fault clears automatically, the user resets it, or the underlying problem is repaired.
The unit uses the same fault code system as most Rheem/Paloma condensing tankless units, so if you’ve worked on any Rheem RTGH or RTG series unit, the codes will look familiar.
| Code | Fault Description | Reset Type |
|---|---|---|
| 00 | Normal operation, no fault | , |
| 03 | Domestic hot water demand too low to ignite (below minimum flow rate) | Auto (increases flow) |
| 05 | Abnormal water pressure (above maximum inlet pressure) | Auto |
| 10 | Exhaust vent blockage detected or insufficient combustion air | Manual |
| 11 | Ignition failure, could not confirm flame during startup attempt | Manual |
| 12 | Flame extinguishment during operation | Manual |
| 14 | Thermal fuse or overheat cutoff device open | Manual (after repair) |
| 16 | Outgoing water temperature exceeded maximum limit | Auto |
| 24 | Secondary heat exchanger outlet temperature sensor failure | Auto |
| 29 | Condensate drain sensor error or condensate system backup | Manual |
| 31 | Inlet cold water temperature sensor failure | Auto |
| 32 | Outlet hot water temperature sensor failure | Auto |
| 33 | Secondary heat exchanger temperature sensor failure | Auto |
| 34 | Ambient temperature sensor failure | Auto |
| 38 | Freeze protection circuit fault | Auto |
| 52 | Modulating gas valve drive circuit failure | Manual |
| 61 | Combustion fan motor failure or incorrect RPM | Manual |
| 65 | Water flow control valve failure | Auto |
| 66 | Bypass valve failure (on units with built-in mixing valve) | Manual |
| 71 | Gas valve circuit failure, valve drive abnormal | Manual |
| 72 | Flame sensing circuit failure, control board issue | Manual |
| 76 | Remote controller communication error | Auto |
| 79 | Inlet water temperature too high (recirculation system issue) | Auto |
| 89 | Gas type mismatch, unit configured for different gas type than supplied | Manual |
The RTGH-95DVLN’s condensing operation is what separates it from standard tankless units. Hot flue gases pass through a stainless steel primary heat exchanger, then through a secondary heat exchanger where additional heat is extracted, dropping flue gas temperatures low enough that water vapor in the exhaust condenses. This condensate (acidic water at pH 3–5) drains out the bottom of the unit through a trap.
Code 24 (secondary HX outlet sensor failure): The temperature sensor monitoring the secondary heat exchanger outlet has gone open-circuit or shorted. This sensor is critical, the secondary heat exchanger can develop lime scale buildup in hard water areas, and the sensor detects if heat transfer is degraded. The sensor is an NTC thermistor; Rheem part RTG20009B covers this sensor on RTGH-series units.
Code 29 (condensate drain fault): This is one of the most common codes on the RTGH-95DVLN in cold climates or installations that weren’t drained properly. The condensate drain system includes a trap (must always have water in it, the trap seal prevents flue gas from entering the room) and, on some installations, a condensate pump. Code 29 appears when:
Never bypass the condensate drain sensor, the RTGH-95DVLN produces roughly 1–3 quarts of condensate per hour at full fire rate. A blocked drain will eventually overflow into the unit and cause internal corrosion.
Code 33 (secondary HX temperature sensor failure): Similar to code 24 but on a different sensor location. Both sensors must be functioning for the unit to operate safely, the secondary heat exchanger can reach damaging temperatures without proper sensor feedback.
| Part | Why You Need It | Approx. Cost |
|---|---|---|
| Rheem Tankless Water Heater Temperature Sensor RTG20009B | Secondary HX and outlet sensors; codes 24, 32, 33 | $20–$45 |
| Condensate Neutralizer Refill Kit | Required if condensate drain is acidic; neutralizes pH before drain | $15–$35 |
| Tankless Water Heater Descaler Flush Kit | Removes scale from secondary heat exchanger; prevents codes 16, 29, 33 | $30–$60 |
| Rheem Combustion Fan AP15516-1 | Replace on code 61; inspect before condemning, check wiring first | $80–$175 |
| Condensate Pump for Tankless Water Heater | Required when gravity drain to floor drain isn’t possible; code 29 prevention | $35–$80 |
| Rheem Igniter Electrode Kit | Replace on code 11 if electrode is fouled or gap is incorrect | $20–$50 |
Need replacement parts? Search for parts and tools on Amazon.
Several RTGH-95DVLN faults require a licensed plumber or HVAC/gas technician:
Inlet filter cleaning, sensor replacement, condensate drain maintenance, and igniter inspection are manageable DIY repairs with basic mechanical aptitude.
Q: The RTGH-95DVLN shows code 29 every winter but works fine in summer. What’s happening? A: Your condensate drain is freezing at the exit point, almost certainly because the drain line runs through or exits near an exterior wall. The condensate exits the unit at close to 50–60°F but can freeze in the drain line if it runs through a cold attic, crawl space, or exterior penetration. The fix is rerouting the condensate to an interior drain or fully insulating the drain line run. A condensate pump that discharges into an interior drain eliminates this problem entirely.
Q: How do I reset error code 11 on my Rheem RTGH-95DVLN? A: Press the temperature UP button on the front panel. On most RTGH revisions, this serves as the reset button. Alternatively, turn the unit off at the power switch, wait 30 seconds, then turn it back on. If the fault reappears immediately, the root cause hasn’t been fixed, don’t just keep resetting.
Q: The unit fires and heats water but code 16 keeps flashing as an alert (not a shutdown). Is it safe to use? A: Code 16 as a non-shutdown alert (some firmware revisions log it as informational if the outlet temperature briefly exceeded the threshold) is a warning. The unit is getting hotter than intended. Turn down the temperature setpoint to 120°F if it’s set higher, check for hot water recirculation sending hot water back to the inlet (which reduces the unit’s ability to control outlet temperature), and plan a descaling service soon. Continuing to operate with code 16 appearing regularly will shorten the heat exchanger life.
Q: My RTGH-95DVLN is brand new and shows code 03 on first start. Is it defective? A: Code 03 means the water flow rate is below the minimum threshold required to fire (typically 0.75 GPM). This often happens on new installations where the service technician is testing the unit with a partially opened tap, or where a pressure-reducing valve was set too low. Open a hot water tap fully and confirm flow, the code should clear and the unit should fire. If it still won’t fire at full open-tap flow, check that both isolation valves on the cold inlet and hot outlet are fully open.
Water-heater faults usually point to ignition, flame sensing, venting, water flow, temperature sensors, scale buildup, or control-board inputs. Confirm gas or electrical supply, clean inlet screens, check venting, and descale tankless units before replacing sensors or boards.
DIY vs Pro: Resetting the unit, cleaning inlet screens, confirming water flow, and basic descaling are owner-level checks. Gas pressure adjustment, combustion testing, high-voltage work, and control-board replacement should be handled by a licensed technician.