Rheem Furnace Igniter Not Working - Causes & Fix

4 min read
⚡ Quick Answer

Most often the igniter element has cracked or failed open. Test it with a multimeter at the leads for continuity and replace if open.

Difficulty Pro recommended
Est. time 1-3 hrs

Rheem Furnace Igniter Not Working — What’s Happening

When a Rheem furnace igniter is not working, the furnace fails to complete its ignition sequence. The igniter may never heat up or glow, or it might heat but the burners never light and the control board aborts the call for heat. This is a symptom rather than a single fault code. Rheem troubleshooting guides point to the full ignition chain, including control board issues, rollout switch trips, flame sensor problems, gas valve operation, and manifold pressure conditions, not just the igniter alone.

Rheem furnaces use either a hot surface igniter or a spark igniter. Both types can fail to work because of a bad igniter element, loose wiring, control board faults, interrupted gas supply, or safety switches that prevent the sequence from starting. Homeowners often see no heat and assume the igniter is bad, but the real cause can be upstream or downstream in the ignition process.

Jump to Fix

Most Likely Causes

How to Diagnose and Fix

  1. Verify the thermostat is calling for heat and confirm that the furnace has power at the service switch and breaker.
  2. Check that the access panel or blower door is fully seated so the door safety switch is closed and the control circuit is enabled.
  3. Identify whether your Rheem furnace uses a hot surface igniter or a spark igniter by inspecting the burner compartment.
  4. Observe the ignition sequence and note whether the igniter glows or sparks, whether the gas valve clicks, and whether the burners light.
  5. Test the hot surface igniter with a multimeter at the igniter leads (disconnect power first). An open or infinite reading means the igniter has failed and must be replaced.
  6. If the igniter glows but the burners do not light, verify the gas cock is open and gas is supplied to the furnace, then check for a failed gas valve or tripped rollout switch.
  7. Inspect the flame sensor rod for heavy soot or corrosion and clean it with fine sandpaper if the burners light briefly then shut off.
  8. Check for a soft lockout condition by turning off power to the furnace for one minute, then restore power and try a new call for heat. If the fault persists, inspect the control board and wiring for damage or loose connections.

Parts You Might Need

PartNotes
Hot surface igniter (Rheem OEM or compatible)Amazon | Match the connector type and mounting bracket to your model.
Spark igniter assemblyAmazon | For models with spark ignition, includes electrode and wire lead.
Flame sensor rodAmazon | Replace if cleaning does not restore continuity or if the ceramic insulator is cracked.

If your appliance also shows a code on the display, these match this problem:

When to Call a Pro

Call a qualified HVAC technician if you are not comfortable working with gas appliances, if testing the igniter requires disassembly you are unsure about, or if basic checks do not isolate the fault. Gas valve replacement, control board diagnosis, manifold pressure testing, and rollout switch investigation all require proper tools and training. A technician can also verify correct combustion, check for carbon monoxide hazards, and reset or replace components that require gas line work or electrical troubleshooting beyond the igniter itself. For gas line, burner, or igniter work, or if you ever smell gas, stop and call a licensed technician.