Skip to content
Industrial Error Code Fixes
Go back

Navien E008 Error Code - Causes & Fix

2 min read
⚡ Quick Answer

E008 means the outlet thermistor circuit is shorted. The most common fix is replacing the outlet temperature sensor or its wiring.

Difficulty Pro recommended
Est. time 1-3 hrs

E008 on your Navien tankless water heater indicates a fault in the outlet temperature sensor circuit, specifically a thermistor short. The outlet thermistor measures the temperature of hot water leaving the heat exchanger. When the control board detects a short in this sensor circuit, it throws E008 and shuts down heating to prevent unsafe operation.

This code falls into Navien’s category of sensor and internal faults, alongside E007 and E036. It is not related to water flow or pressure issues. The fault almost always involves the outlet thermistor itself or the wiring and connector that link it to the control board.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Confirm the error code on the display panel and verify it reads E008, not E007, E036, or a flow-related fault.
  2. Power off the unit at the service disconnect or circuit breaker and allow a few minutes for capacitors to discharge before opening any panels.
  3. Locate the outlet thermistor on the hot water side of the heat exchanger and inspect the sensor body, wiring, and connector for visible damage, corrosion, moisture, or pinched wires.
  4. Disconnect the thermistor connector and use a multimeter to measure the resistance across the sensor leads, comparing the reading to the specification chart in your model’s service manual.
  5. Replace the outlet thermistor if the resistance reading is out of range or if the sensor shows a short (zero or near-zero resistance at room temperature).
  6. Repair or replace the wiring harness if the sensor tests good but the wiring or connector shows damage, corrosion, or poor contact.
  7. Clear the fault code by restoring power and running a hot water tap to verify the heater fires without error, then monitor for 24 hours to confirm the repair holds.

Parts Often Needed

PartNotes
Navien outlet thermistor / hot water outlet temperature sensorAmazon | Verify the exact part number for your Navien model before ordering, as sensors vary by series.
Thermistor wiring harness or connectorAmazon | Order if the sensor is intact but the wiring or plug is damaged beyond repair.

When to Call a Pro

If you are uncomfortable working inside a tankless water heater cabinet, measuring electrical resistance, or identifying the outlet thermistor circuit, contact a licensed plumber or Navien-certified technician. Also call a pro if replacing the sensor and harness does not clear E008, if the code returns intermittently, or if you see other fault codes alongside E008. Navien technical support can help your technician diagnose complex board or heat exchanger issues when you have the unit’s serial number ready.