⚡ Quick Answer

CH21 error (compressor overcurrent/IPM fault) is most common, caused by inverter PCB failure, compressor defect, or power supply issues.

Difficulty Intermediate
Est. time 15-60 min

LG LS120HSV5 Ductless Mini Split Problems & Error Codes — Overview

The LG LS120HSV5 / LSN120HSV5 ductless mini split uses inverter-driven compressor technology to provide efficient heating and cooling. The most frequent repair issue on this model family is the CH21 error code, which LG defines as a DC peak / IPM fault / compressor overcurrent condition in the inverter system. This fault means the outdoor unit’s inverter PCB detected abnormal compressor drive current or triggered a protection event in the drive stage, not a simple filter or remote problem.

Other common issues include blinking lamp codes (CH 00 requiring inspection per LG support documentation), power supply and wiring faults that starve the inverter, and restricted outdoor airflow that can push the compressor into overload protection. Because this platform relies on precise inverter control and high insulation standards (above 10 MΩ phase-to-ground per LG service specs), electrical problems in the compressor windings or IPM module account for the majority of no-cool and protection-shutdown calls.

Jump to Common Problems

Most Common Problems on This Model

Parts That Commonly Fail

PartNotes
Inverter PCB / IPM moduleAmazon | Fails with carbonization, burn marks, or DC peak / IPM fault triggering CH21 code.
CompressorAmazon | Defective when phase resistance is unequal or insulation resistance drops below 10 MΩ to ground.
EEV coil harnessAmazon | Connector corrosion or loose seating at outdoor main PCB disrupts refrigerant control.
Power supply wiring and connectorsAmazon | Loose or undersized wiring causes voltage drop and inverter protection shutdown.

When to Call a Pro

Call a licensed HVAC technician for any CH21 or protection code, compressor electrical testing (phase resistance and insulation resistance), or inverter PCB diagnostics. Measuring DC link voltage at P–N terminals (310 V DC single-phase, 540 V DC three-phase per LG specs), checking diode behavior between phases, inspecting for carbonization on the IPM, and performing compressor insulation tests above 10 MΩ all require a meter and refrigeration knowledge. Compressor or inverter PCB replacement also means recovering refrigerant, brazing, evacuation, and recharge, which are EPA-certified tasks. If you see burn marks, smell electrical odor, or the unit trips your breaker repeatedly, shut off power at the disconnect and call a pro immediately.