⚡ Quick Answer

CH21 error code is the most common failure, caused by compressor overcurrent or inverter board faults requiring outdoor unit service.

Difficulty Intermediate
Est. time 15-60 min

LG LAN120HSV5 Ductless Mini Split Problems & Error Codes — Overview

The LG LAN120HSV5 is a ductless mini split air conditioner that relies on inverter-driven compressor technology for variable-speed cooling. The most frequent field problems center on the outdoor unit’s inverter control and compressor protection logic, particularly the CH21 fault code that indicates excessive current draw at the compressor or inverter. This error is treated by LG as a compressor lock or inverter overcurrent condition, not a simple sensor glitch, and requires outdoor unit inspection and testing. Other issues include refrigerant leaks, outdoor fan motor failures, and indoor unit airflow restrictions that reduce system capacity.

Jump to Common Problems

Most Common Problems on This Model

Parts That Commonly Fail

PartNotes
Inverter PCB / IPM moduleAmazon | Outdoor board that drives the compressor; fails with carbonization, burn marks, or shorted IPM, triggering CH21.
CompressorAmazon | Inverter-driven scroll compressor; fails with winding imbalance, insulation breakdown below 10 MΩ, or mechanical lock.
Outdoor fan motorAmazon | Condenser fan motor in outdoor unit; fails due to bearing wear or winding damage, reducing heat rejection.
Electronic expansion valve (EEV) harnessAmazon | Connector and wiring to EEV at outdoor unit; loose or damaged connections contribute to inverter faults.

When to Call a Pro

Call a licensed HVAC technician for any CH error code that does not clear after a full power cycle, for any compressor or inverter diagnostics requiring measurement of phase-to-phase resistance or insulation resistance, and for refrigerant leak repair or system recharge. Inverter PCB and compressor replacement both require refrigerant recovery, vacuum, and proper brazing, and the outdoor unit must be electrically isolated and tested with a megohmmeter and multimeter to identify the root cause of overcurrent faults. Supply voltage issues at the breaker panel and any work inside the outdoor unit electrical compartment should be handled by a qualified technician.