Lennox SL297NV guide for iComfort faults, ignition lockout, pressure-switch errors, limit trips, ECM blower faults, and inducer checks.
Lennox SL297NV guide for iComfort faults, ignition lockout, pressure-switch errors, limit trips, ECM blower faults, and inducer checks.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Lennox SL297NV is among the highest-efficiency gas furnaces on the market, achieving up to 97.5% AFUE through a two-stage gas valve, variable-speed ECM blower motor, and modulating inducer. It integrates natively with the iComfort S30 and iComfort E30 smart thermostats to provide rich diagnostic data, far more detail than you’d get from most furnaces.
When the SL297NV faults, it logs codes accessible from the iComfort thermostat AND blinks them on the control board LED. This guide decodes both systems and tells you exactly what to check.
The SL297NV uses a two-LED system on the control board: a green LED for power/status and an amber LED for fault indication. Read the amber LED only.
Blink pattern: Count blinks, pause, count again. First number = fault category, second number = specific fault within that category (e.g., 3 blinks, pause, 2 blinks = fault 3-2).
If you have an iComfort thermostat, navigate to Menu → Diagnostics → Fault History for full alphanumeric codes, timestamps, and recommended actions.
| LED Sequence | iComfort Code | Description |
|---|---|---|
| 1-1 | E001 | Ignition failure, no flame established |
| 1-2 | E002 | Ignition lockout (repeated failure) |
| 1-3 | E003 | Flame signal lost during run |
| 2-1 | E021 | Pressure switch stuck open |
| 2-2 | E022 | Pressure switch stuck closed |
| 2-3 | E023 | Secondary pressure switch fault |
| 3-1 | E031 | High-limit switch open |
| 3-2 | E032 | Rollout switch open |
| 3-3 | E033 | Auxiliary limit switch open |
| 4-1 | E041 | Inducer motor fault |
| 4-2 | E042 | Variable-speed blower motor fault (ECM) |
| 4-3 | E043 | Blower motor communication fault |
| 5-1 | E051 | Gas valve fault |
| 5-2 | E052 | Hot surface igniter circuit fault |
| 6-1 | E061 | Control board internal fault |
| 6-2 | E062 | EEPROM fault |
| 7-1 | E071 | iComfort communication fault |
These are the most common faults on the SL297NV. The furnace attempts to light, the flame sensor doesn’t confirm a flame, and the board shuts the gas valve.
The pressure switch confirms the inducer is creating adequate draft before allowing the gas valve to open.
A switch that reads closed before the inducer starts prevents furnace operation.
The high-limit switch cuts the gas valve when the heat exchanger exceeds a safe temperature (typically around 180°F on the SL297NV).
A rollout switch opening is serious. It means flames are rolling out of the combustion chamber rather than being drawn through the heat exchanger into the flue.
The variable-speed ECM motor in the SL297NV communicates digitally with the control board. These faults appear when the motor fails to respond or reports an internal fault.
| Part | Use | Link |
|---|---|---|
| Hot Surface Igniter (Silicon Nitride) | E001/E002 ignition faults | |
| Flame Sensor Rod | E001 flame sensing failure | |
| Furnace Pressure Switch | E021/E022 pressure switch faults | |
| Pressure Switch Tubing | E021 hose cracks or disconnects | |
| Furnace High-Limit Switch | E031 persistent high-limit open | |
| Lennox Inducer Motor Assembly | E041 inducer motor fault |
Need replacement parts? Search for parts and tools on Amazon.
DIY-safe repairs on the SL297NV:
Call a licensed technician immediately for:
How do I access the full fault history on the iComfort S30? Go to the thermostat home screen → Menu → Diagnostics → Fault History. You’ll see the last 10 faults with dates, times, and detailed descriptions. This is far more useful than the LED codes alone.
My SL297NV starts, fires for a few seconds, then shuts off. What’s happening? This is almost always the flame sensor. The igniter lights the burner, but the flame sensor (covered in carbon deposits or failing) can’t confirm a flame to the control board, so the board cuts the gas valve as a safety measure. Clean the flame sensor first, it’s a 10-minute job with a 90% success rate for this symptom.
The furnace runs but the ECM blower seems to run slower than normal. Should I be worried? The SL297NV’s variable-speed ECM is designed to vary speed based on system demand and static pressure. Running at lower speed on mild days is completely normal. It only becomes a fault if the blower can’t meet heating demand or if Code E042 appears. If you suspect the motor speed is lower than it should be under load, have a technician check the motor speed profile settings in the control board.
How efficient is the SL297NV, and does running it in fault-reset mode affect efficiency? The SL297NV achieves up to 97.5% AFUE in two-stage operation. Frequent fault resets, especially ignition lockouts, cause the furnace to run in open-loop mode during re-ignition attempts, which is less efficient and stresses components. Repeated lockouts mean a real problem needs to be fixed, not just reset.
The rollout switch tripped once. Can I just reset it and keep going? No. A rollout switch trip is a serious indicator of either a blocked flue, failed inducer, or a cracked heat exchanger. Any of these can result in carbon monoxide intrusion. Reset only after a thorough visual inspection, and if the cause is not obvious, call a technician before running the furnace again.
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.