Keeprite is a Canadian HVAC brand that uses the same ICP (International Comfort Products) platform as Heil, Tempstar, and Comfortmaker. E1 on a Keeprite furnace indicates a pressure switch fault — the induced draft motor ran but the pressure switch failed to close within the startup window, locking out the ignition sequence. The code clears when the root cause is corrected and the furnace is power-cycled.
| Part | Notes |
|---|---|
| Pressure switch | Use Keeprite/ICP part number; pressure rating stamped on switch body |
| Pressure switch hose | 1/4” ID; silicone preferred for cold-climate durability |
| Inducer motor capacitor | Test first — often fixes slow inducer at a fraction of motor cost |
| Induced draft motor | Replace if capacitor is good but motor is loud, slow, or seized |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
In regions with extreme cold, repeated E1 codes from icing require a licensed HVAC technician to evaluate vent routing and possibly install an approved vent cap with freeze protection. Do not operate the furnace with a partially blocked flue.