Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Diagnose ICP Furnace E4 Error Code - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Diagnose ICP Furnace E4 Error Code - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
E4 on an ICP furnace (International Comfort Products — the parent platform for Heil, Tempstar, Comfortmaker, and Day & Night) indicates an open limit circuit. The high-temperature limit switch or rollout switch has opened, cutting power to the gas valve and stopping heating. Unlike E1 (pressure switch), E4 points specifically to the limit/rollout safety chain. The furnace will not restart until the limit device resets and the E4 is cleared.
| Part | Notes |
|---|---|
| Air filter | Always first check on E4 |
| High-limit switch | Auto or manual reset; verify trip temperature matches OEM spec |
| Rollout limit switch | Manual reset only; replace if reset button does not hold |
| Blower run capacitor | Inexpensive first test before replacing the blower motor |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
A tripped rollout switch indicates flames are escaping the burner box — potentially caused by a cracked heat exchanger or blocked flue. Do not operate the furnace after a rollout trip until a licensed technician inspects the heat exchanger and venting for safety.