Thermistor
Common temperature-sensing fault part. Confirm resistance range and connector.
Troubleshoot Hoshizaki E5 on refrigeration equipment with checks for sensors, airflow, condenser condition, controls, and parts to price first.
Troubleshoot Hoshizaki E5 on refrigeration equipment with checks for sensors, airflow, condenser condition, controls, and parts to price first.
Likely parts to price
Common temperature-sensing fault part. Confirm resistance range and connector.
Useful to price for airflow, warm cabinet, or coil-icing symptoms.
Check this on ice buildup and defrost-cycle failures.
Low-risk maintenance item for water-flow and ice-quality complaints.
Hoshizaki error code E5 means high-temperature shutdown — the control board detected that ice machine temperatures rose above the safe operating limit during the freeze cycle and triggered a protective shutdown. On Hoshizaki KM and KML series cubers, the control monitors both evaporator and ambient temperatures. E5 typically indicates that the refrigeration system couldn’t maintain freeze cycle conditions within the expected time, or that the machine room ambient temperature exceeded the unit’s operating range. The machine will not make ice while E5 is active.
| Part | Notes |
|---|---|
| Condenser fan motor | Match OEM spec; Hoshizaki uses specific RPM and CFM ratings |
| Condenser fan blade | Replace if cracked or damaged; damaged blades reduce airflow significantly |
| Condenser coil cleaner | Nu-Calgon Coil King foam cleaner; rinse thoroughly |
When diagnosing commercial refrigeration faults, start with the controller’s alarm history. Most digital controllers (Dixell, Carel, Eliwell) store the last 5-10 alarms with timestamps. An E1 alarm that appears consistently every few hours suggests a sensor going bad — the resistance value drifts until it’s out of range. An intermittent HI/LO alarm that appears only during hot afternoons suggests a condenser issue, not a sensor fault.
Prevention: Schedule quarterly condenser coil cleaning. Dirty coils are the #1 cause of high-head-pressure faults and compressor overheating in commercial refrigeration. Use a soft brush and compressed air — never a pressure washer on the coil fins.
Before ordering, match the ice-machine part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the condenser is clean, fan is running, and ambient temperature is acceptable, but E5 persists, the refrigerant system needs pressure testing. A certified refrigeration technician can diagnose high-side pressure and compressor condition.