Cooling fan
Common VFD, drive, UPS, and cabinet overheating failure point.
Diagnose Fanuc Alarm 2 - Overtravel Plus Causes & Fix: what triggers the alarm, checks to run, and repair decisions before clearing the machine.
Diagnose Fanuc Alarm 2 - Overtravel Plus Causes & Fix: what triggers the alarm, checks to run, and repair decisions before clearing the machine.
Likely parts to price
Common VFD, drive, UPS, and cabinet overheating failure point.
Useful to price when faults involve display, keypad, or operator-panel behavior.
Low-cost first check for power-stage and line-side faults.
Price this on drive overvoltage, braking, or deceleration faults.
Fanuc Alarm 2 is an Overtravel (Plus direction) hardware limit — an axis has tripped the positive hardware overtravel limit switch. Unlike the software overtravel limits (set in parameters), the hardware OT switch is a physical limit switch wired directly to the CNC as a safety interlock. When the machine axis travels beyond the positive hardware limit, the drive cuts out and Alarm 2 is stored. The machine will not move the faulted axis in any direction except back off the limit switch using the override procedure.
| Part | Notes |
|---|---|
| Overtravel limit switch | Replace if the switch actuates at the wrong position or shows intermittent behavior |
| Limit switch cable | If wiring to the OT switch is chafed or broken |
CNC alarms should always be diagnosed by reading the full alarm text, not just the number. Modern Fanuc, Haas, and Mazak controls provide detailed alarm descriptions — press the help key while viewing the alarm for diagnostic suggestions. The alarm history screen stores the last 50-100 alarms with timestamps; review this before clearing to identify patterns. A servo alarm (SV series on Fanuc) that appears only during rapid traverse points to a different cause than one that appears during cutting.
Prevention: Back up your CNC parameters monthly. Battery-backed memory faults are much easier to recover when you have a current parameter, ladder, offset, and macro backup. Replace control batteries on a planned maintenance schedule before voltage drops far enough to risk data loss.
Before ordering, match the machine-control part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the machine homes incorrectly after clearing Alarm 2, the absolute encoder battery may be dead or the reference mark may be lost. Incorrect homing on multi-axis machines can cause crashes — have a Fanuc-trained service engineer verify the reference point before resuming production.