Skip to content
Industrial Error Code Fixes
Go back

Fanuc Alarm 2 — Overtravel Plus Causes & Fix

⚡ Quick Answer

Diagnose Fanuc Alarm 2 - Overtravel Plus Causes & Fix: what triggers the alarm, checks to run, and repair decisions before clearing the machine.

⚡ AT A GLANCEScroll down for full repair guide
What it meansDiagnose Fanuc Alarm 2 - Overtravel Plus Causes & Fix: what triggers the alarm, checks to run, and repair decisions before clearing the machine.
Most likely causeMost CNC faults come from servo load, spindle load, cabinet cooling, drive power, encoder feedback, or parameter conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact alarm text, check cabinet cooling and obvious axis or spindle load, then follow the model-specific checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededCooling fan
Repair intent

Need this fixed instead of diagnosed?

Diagnose Fanuc Alarm 2 - Overtravel Plus Causes & Fix: what triggers the alarm, checks to run, and repair decisions before clearing the machine.

Likely parts to price

Price the common parts before you book service.

Cooling fan

Common VFD, drive, UPS, and cabinet overheating failure point.

Control keypad

Useful to price when faults involve display, keypad, or operator-panel behavior.

Fuses

Low-cost first check for power-stage and line-side faults.

Braking resistor

Price this on drive overvoltage, braking, or deceleration faults.

Fanuc Alarm 2 — Overtravel Plus: What It Means

Fanuc Alarm 2 is an Overtravel (Plus direction) hardware limit — an axis has tripped the positive hardware overtravel limit switch. Unlike the software overtravel limits (set in parameters), the hardware OT switch is a physical limit switch wired directly to the CNC as a safety interlock. When the machine axis travels beyond the positive hardware limit, the drive cuts out and Alarm 2 is stored. The machine will not move the faulted axis in any direction except back off the limit switch using the override procedure.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Activate OT release function — On most Fanuc systems, press and hold the OT Release (or Hardware OT Release) function key on the MDI panel, or hold the appropriate button combination per your machine’s operation manual. This temporarily overrides the hardware OT signal.
  2. Jog axis off the limit — While holding OT release, use the handwheel or manual jog to move the axis in the minus direction (away from the positive hardware limit). Move just far enough to clear the limit switch — typically 5–10mm is sufficient.
  3. Release the OT release button — Once the axis is clear, release the OT release button. Alarm 2 should clear.
  4. Verify axis position — Check the current machine coordinate position. If the position looks incorrect relative to the known physical position, perform a machine reference (home) cycle.
  5. Check soft limit parameters — In MDI, access Parameter mode and verify that the positive software limit (Parameter 1320 for each axis) is set inside the physical hardware limit by at least 5mm.
  6. Inspect the OT switch — If the alarm tripped without apparent cause, check the hardware limit switch for physical shift, contamination, or cable damage.

Parts Often Needed

PartNotes
Overtravel limit switchReplace if the switch actuates at the wrong position or shows intermittent behavior
Limit switch cableIf wiring to the OT switch is chafed or broken

Technician Tips

CNC alarms should always be diagnosed by reading the full alarm text, not just the number. Modern Fanuc, Haas, and Mazak controls provide detailed alarm descriptions — press the help key while viewing the alarm for diagnostic suggestions. The alarm history screen stores the last 50-100 alarms with timestamps; review this before clearing to identify patterns. A servo alarm (SV series on Fanuc) that appears only during rapid traverse points to a different cause than one that appears during cutting.

Prevention: Back up your CNC parameters monthly. Battery-backed memory faults are much easier to recover when you have a current parameter, ladder, offset, and macro backup. Replace control batteries on a planned maintenance schedule before voltage drops far enough to risk data loss.

Need Replacement Parts?

Before ordering, match the machine-control part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If the machine homes incorrectly after clearing Alarm 2, the absolute encoder battery may be dead or the reference mark may be lost. Incorrect homing on multi-axis machines can cause crashes — have a Fanuc-trained service engineer verify the reference point before resuming production.


Share this post on:

Previous Post
Fanuc Alarm 424 — Causes & Fix
Next Post
Fanuc Alarm 3 — Overtravel Minus Hardware Causes & Fix