Danfoss FC302 Alarm 38 - Causes & Fix

2 min read
⚡ Quick Answer

Danfoss FC302 Alarm 38 means internal fault, usually a communication error between control and power cards. Reset steps inside.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Danfoss FC302 Alarm 38 — What It Means

Alarm 38 on the Danfoss VLT FC302 indicates an internal fault. This is not a single field-replaceable failure but a broad category that requires further diagnosis. The drive will display a subcode to help narrow down the problem. According to Danfoss technical support, the most common cause of Alarm 38 is a communication error between the control card and the power card inside the drive. The fault can appear after a disturbance, maintenance work, or component failure that interrupts the internal signal path between these boards.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Cycle power by switching off the drive, waiting 30 seconds, and powering it back on to attempt a reset as Danfoss recommends.
  2. Note the displayed subcode or any additional numbers shown with Alarm 38 and write them down for reference.
  3. Power down completely and lock out the drive, then open the enclosure to access the internal boards.
  4. Inspect and reseat all internal connections, paying special attention to the ribbon cables and connectors between the control card and power card, and check that any installed option cards are firmly seated.
  5. Look for physical damage such as burn marks, corrosion, or loose solder joints on the control card, power card, and interconnects.
  6. Power up and test the drive after reseating connections to see if the fault clears.
  7. Contact Danfoss technical support with your drive model, serial number, and subcode if the alarm persists, because the exact internal fault code determines which board requires replacement.

Parts Often Needed

PartNotes
Danfoss FC302 Control CardAmazon | Required if diagnostics or Danfoss support confirm control-side communication failure.
Danfoss FC302 Power CardAmazon | Needed when the power section is not responding to the control board.
Internal Ribbon Cable or Connector KitAmazon | Use if visual inspection shows damaged or broken interconnects between boards.

When to Call a Pro

Call a qualified VFD technician or contact Danfoss technical support if cycling power and reseating internal connections does not clear Alarm 38. Internal board diagnosis requires knowledge of the specific subcode, access to internal schematics, and safe handling of live power electronics. If you are not trained to open and service the drive or lack the tools to isolate board-level faults, professional repair or factory service is the safest route. Danfoss support can guide board replacement based on the exact fault code displayed.