Temperature sensor
Common error-code part. Confirm resistance and connector style.
Daikin Aurora guide for A1, A3, A6, C4, E3, E7, F3, H6, U2, and U4 faults on cold-climate inverter heat pumps.
Daikin Aurora guide for A1, A3, A6, C4, E3, E7, F3, H6, U2, and U4 faults on cold-climate inverter heat pumps.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
The Daikin Aurora is Daikin’s purpose-built cold-climate heat pump, designed to deliver heat at outdoor temperatures as low as -13°F (-25°C). This makes it one of the most capable cold-climate heat pumps on the market, but its sophisticated variable-speed inverter compressor and extended operating range also mean a more complex fault code system than standard heat pumps. When your Aurora stops heating or cooling, the error code it stores is your fastest path to diagnosis.
The Aurora uses Daikin’s standard alphanumeric fault code system, accessible through the thermostat or through the service button on the outdoor unit control board. Error codes use letters and numbers in a two to three character format. The first character indicates the subsystem; the digits indicate the specific fault within that subsystem.
Accessing codes via thermostat: On Daikin’s communicating thermostat, navigate to Menu → Information → Error History. Codes appear with timestamps.
Accessing codes via outdoor unit: Press the service check button on the outdoor unit control board. The LED will flash a pattern: short flashes indicate the first character, long flashes indicate the second.
A1 , Indoor Unit PCB Fault The indoor air handler’s printed circuit board (PCB) has detected an internal fault. This code indicates a PCB component failure , check for obvious signs of damage (burnt components, swollen capacitors). If the board is in warranty, Daikin typically replaces it without charge for covered units.
A3 , Indoor Unit Drain Fault The indoor unit’s float switch has tripped, indicating the condensate drain pan is full. On the Aurora, this code is more common in cooling season. Clear the condensate drain line immediately using a wet-dry vacuum. Check that the drain line is sloped at least 1/4 inch per foot toward the drain outlet.
A6 , Indoor Fan Motor Fault The indoor blower motor or its driver circuit has faulted. On Aurora air handlers, the ECM (electronically commutated motor) fan can develop issues after 5–8 years. Check the motor connector for corrosion and verify the motor shaft spins freely. The Aurora’s indoor fan motor is controlled by the main PCB via a PWM signal , if the board doesn’t get the expected tachometer feedback, it logs A6.
C4 , Indoor Coil Thermistor Open/Short The thermistor (temperature sensor) on the indoor coil has failed open or shorted. This sensor is critical for refrigerant control. The Aurora’s electronic expansion valve (EEV) uses this data to regulate refrigerant superheat. A failed C4 sensor causes the system to run inefficiently and eventually fault. Replace the sensor.
C9 , Outdoor Coil Thermistor Open/Short Same failure type as C4, but on the outdoor coil sensor. In cold climate heat pump operation, this sensor is critical for defrost timing and compressor protection. A failed C9 sensor may cause excessive icing or insufficient heating at low outdoor temperatures.
E1 , Outdoor Unit PCB Fault The outdoor unit’s main control board has detected an internal fault. This often means board replacement. Before replacing, check for water intrusion in the outdoor unit cabinet (check all wiring penetration seals) and check for obvious component damage on the board.
E3 , High-Pressure Switch Trip The refrigerant high-pressure protection switch has tripped. In cooling mode: dirty outdoor coil, failed outdoor fan motor, refrigerant overcharge, or extremely high ambient temperature. In heating mode (more common on cold climate units): dirty indoor coil, indoor fan not running, or restriction in refrigerant circuit. Clean the appropriate coil and verify fan operation.
E4 , Low-Pressure Protection The system has detected low refrigerant pressure. On the Aurora, this code takes on additional significance because cold-climate heat pumps operating at extreme low temperatures inherently run at lower suction pressures. E4 at moderate outdoor temperatures (above 10°F) typically indicates a refrigerant leak or expansion valve problem. E4 at extreme temperatures (below -10°F) may be within normal operation range for some fault detection scenarios , check the installation manual for the Aurora’s specific operating limits.
E7 , Outdoor Fan Motor Fault The Aurora’s outdoor fan motor has faulted. Cold climate operation puts additional stress on outdoor fan motors due to potential icing and low-temperature operation. Verify the fan blade spins freely (with power off). Check for ice accumulation around the fan , a common issue in heavy snowfall if the unit is improperly sited. Check motor winding resistance: should be within 10% across all winding pairs.
F3 , Discharge Pipe Thermistor Fault The compressor discharge temperature thermistor has failed. This sensor directly monitors compressor outlet temperature and is critical for the Aurora’s compressor protection at extreme low ambient temperatures. Without accurate discharge temperature data, the Aurora’s inverter cannot properly protect the compressor. Replace the sensor immediately.
L5 , Power Module Overload (Overcurrent) The inverter power module detected an overcurrent condition. On the Aurora, L5 is often associated with cold starts (attempting to run the compressor at full speed in extreme cold without adequate oil return). The Aurora has a low-ambient start sequence, but a failed start procedure or compressor mechanical issue triggers L5. Allow the system to warm for 30 minutes and retry. If L5 appears consistently at normal temperatures, the compressor may be starting to fail.
U2 , Low Voltage / Power Supply Fault Supply voltage to the outdoor unit has dropped below safe operating levels. The Aurora’s inverter is voltage-sensitive. Measure supply voltage at the outdoor unit disconnect: should be within 10% of nameplate (208–230V or 240V depending on installation). Low voltage at startup is a common issue on long wire runs from the main panel.
U4 , Communication Error (Indoor to Outdoor) The indoor and outdoor units have lost communication. The Aurora uses a proprietary communication protocol over the S21 signal wire. Check all inter-unit wiring, particularly at the terminal block. The S21 wire must not be in the same conduit as high-voltage wiring.
UF , Outdoor Fan or Compressor Locked Rotor A locked rotor condition detected in either the outdoor fan motor or the compressor. This is a hard fault requiring immediate shutdown. For the outdoor fan, check for physical obstruction (ice, debris). For the compressor, this may indicate mechanical failure , do not continue to attempt restarts.
The Daikin Aurora is rated to operate down to -13°F for heating. However, several fault codes manifest differently in extreme cold:
| Part | Use | Buy on |
|---|---|---|
| Daikin Compatible 10K Coil Thermistor | Replace C4 or C9 sensors | |
| Condensate Drain Line Cleaning Tablets (Rectorseal) | Prevent A3 drain faults by keeping drain clear | |
| 14/4 Multi-Conductor HVAC Wire (50 ft) | Replace communication and control wiring for U4 | |
| Digital Refrigerant Gauge Set (R-410A) | Check refrigerant pressures for E3, E4 diagnosis | |
| HVAC Digital Multimeter (Fluke 116) | Test voltage, motor resistance, and sensor values | |
| Outdoor Unit Winter Cover / Wind Baffle | Protect Aurora outdoor unit in extreme cold climates |
Need replacement parts? Search for parts and tools on Amazon.
Q: My Daikin Aurora runs in defrost mode very frequently when it’s below 20°F outside. Is this normal or a fault? A: On cold-climate heat pumps, defrost frequency increases significantly at low ambient temperatures because the outdoor coil accumulates frost rapidly. Defrost cycles every 30–60 minutes at 10–20°F outdoor temperature is normal for the Aurora operating at full heating capacity. If defrost runs but doesn’t complete (you see error U4 or E4 immediately after defrost), then there is a fault in the defrost termination circuit.
Q: The Daikin Aurora shows a fault code then clears it on its own without me doing anything. Should I be concerned? A: Yes. Self-clearing fault codes indicate intermittent faults that the system can recover from automatically , but intermittent faults are often early-stage hardware failures. Log every fault code with its timestamp. If the same code appears repeatedly over a few weeks, schedule a service call before it becomes a system-down failure.
Q: Can the Daikin Aurora operate during a power outage if I have a backup generator? A: Yes, but the generator output must be clean sine wave (not modified sine wave) and sized appropriately. The Aurora’s inverter compressor requires clean AC power. Modified sine wave generators cause inverter faults (U2, E1). A properly sized whole-home inverter generator of at least 5,000W continuous output is needed for a typical Aurora system.
Q: My Aurora shows E4 (low pressure) but only during cooling, not heating. Is that consistent with a refrigerant leak? A: Refrigerant leaks will typically manifest during both heating and cooling, but the symptoms are more severe in cooling mode (where suction pressures are naturally lower). A leak that causes E4 in cooling but not obvious symptoms in heating suggests a small, slow leak. Have a technician check static refrigerant pressure and perform a leak search.
Heat pump error codes often signal one of two problems: a defrost cycle failure or a refrigerant issue. If the auxiliary heat indicator on your thermostat is constantly on, the system is running in emergency heat mode — check for ice buildup on the outdoor unit. Heat pumps with communicating thermostats (Carrier Infinity, Bryant Evolution, Lennox iComfort) store detailed fault codes in the thermostat’s installer menu that aren’t shown to homeowners. Accessing these requires the installer code — typically found in the installation manual.
Defrost cycle: A normal defrost cycle lasts 5-15 minutes. If the outdoor unit stays iced up for more than 30 minutes with the system running, the defrost board, sensor, or thermostat has failed.