Common overcrank fix on RV QG units that sat with old fuel.
Cummins Onan generator fault guide for RV QG, RS, and MDKD codes, overcrank, underspeed, oil pressure, AVR, and service parts.
Cummins Onan generator fault guide for RV QG, RS, and MDKD codes, overcrank, underspeed, oil pressure, AVR, and service parts.
Parts to price first
Part: Onan QG carburetor
Common overcrank fix on RV QG units that sat with old fuel.
Part: Onan AVR
Price after confirming field or voltage fault diagnostics.
Part: Onan oil pressure sender
Check when low-oil shutdown persists after oil level is correct.
Part: Onan QG fuel filter
Match the QG or QD model before replacing filters for overcrank and fuel-delivery faults.
Part: Onan QG spark plug
Use for RV overcrank faults after confirming fuel level, choke movement, and battery condition.
Part: Onan QG air filter
Match housing shape and model number before replacing restricted intake filters.
Cummins Onan generators cover the range from compact RV gensets (QG 2500, QD 3200) to commercial diesel generators (MDKD, DSGAA series). Fault codes are displayed on the generator control panel or via the Onan app. RV-series generators use a simplified blink code system.
Need a broader lookup? The generator fault-code hub compares Onan blink codes with Generac, Kohler, Cummins PowerCommand, Honda, Champion, Westinghouse, Briggs, and DuroMax faults.
| Code | Series | Meaning | Quick Fix |
|---|---|---|---|
| 2 blinks | RV QG/QD | Low oil pressure | Add oil; check oil sender |
| 3 blinks | RV QG/QD | High coolant temperature | Check coolant; check fan |
| 4 blinks | RV QG/QD | Overcrank (fail to start) | Check fuel, spark, choke |
| 5 blinks | RV QG/QD | Field (voltage) fault | AVR or control board issue |
| 6 blinks | RV QG/QD | Governor fault | Governor calibration needed |
| 7 blinks | RV QG/QD | Controller fault | Replace control board |
| 8 blinks | RV QG/QD | Low voltage / high voltage | Load issue or AVR fault |
| Code 13 | Commercial | Low oil pressure warning | Check oil level |
| Code 14 | Commercial | Low oil pressure shutdown | Immediate shutdown - add oil |
| Code 22 | Commercial | High coolant temp warning | Check cooling system |
| Code 23 | Commercial | High coolant temp shutdown | Stop generator; check coolant |
| Code 35 | Commercial | Engine fail to start | Check fuel, battery, starter |
| Code 36 | Commercial | Engine overspeed | Governor problem |
| Code 45 | Commercial | Low fuel | Refuel |
| Code 54 | Commercial | Battery charger fault | Check charger AC supply |
RV Generators (QG 2500, QD 3200): The most common failure on RV Onan generators. Root causes by frequency:
For RV generators: use SAE 30 or 10W-30 per the Onan manual. Check the dipstick. If oil level is correct and the generator immediately shuts down on restart, the oil pressure sender may be failed. Bypass test: a technician can temporarily jumper the oil pressure switch to verify the engine actually has oil pressure.
The generator’s field excitation circuit has a fault. This is usually the AVR (automatic voltage regulator) or the excitation winding in the alternator. The AVR on Onan QG/QD generators is a small board inside the control compartment. Inspect for burned components or loose connectors. If the AVR board shows burn damage, replace it.
On liquid-cooled commercial Onan generators, check the coolant level, radiator fins, thermostat, and water pump impeller. On the air-cooled RV QG series, check that the generator’s cooling air inlet and exhaust openings are not blocked by debris or insulation material.
Onan commercial generators (MDKD, DSGAA) use a mechanical governor with electronic trim. Overspeed faults indicate the governor has lost control. Check the governor actuator wiring first — a failed or disconnected actuator is a common cause. On mechanical governors, check the flyweight assembly and governor spring.
| Service Item | Interval |
|---|---|
| Engine oil | Every 150 hours or annually |
| Air filter | Every 150 hours |
| Spark plugs | Every 150 hours |
| Fuel filter | Every 150 hours |
| Carburetor cleaning | As needed (every 2–3 seasons if run infrequently) |
Before ordering, match the generator part to the model number, electrical rating, and failure symptom:
Onan commercial generator faults (Code 22+, voltage faults, governor faults) require a Cummins-authorized service center. Do not attempt to adjust AVR or governor settings without proper test equipment and Onan service training.
Four blinks usually mean an overcrank or fail-to-start fault. Check fuel level, fuel pickup, carburetor varnish, choke operation, spark plugs, and battery condition.
Two blinks point to low oil pressure on many RV Onan units. Check oil level and oil grade first, then test the oil pressure sender if the level is correct.
Five blinks indicates a field or voltage fault. Inspect the AVR, excitation wiring, and alternator field circuit before replacing the control board.