Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Comfortmaker E1 means furnace lockout after ignition, pressure-switch, limit, or rollout faults. Check flame sensing, airflow, venting, and switches.
Comfortmaker E1 means furnace lockout after ignition, pressure-switch, limit, or rollout faults. Check flame sensing, airflow, venting, and switches.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Comfortmaker E1 error code is a system lockout — the furnace has exceeded the maximum number of ignition retry attempts or has tripped a safety device (pressure switch, high-limit, or rollout switch) enough times to trigger a hard lockout. The control board will not allow another heating attempt until the fault is manually reset or the lockout timer expires. Comfortmaker furnaces are ICP/Carrier products and share the same control platform as Heil, Tempstar, and Arcoaire.
| Part | Notes |
|---|---|
| Flame sensor rod | Address ignition lockouts first — easiest and cheapest fix |
| Air filter | For limit lockouts; replace and confirm blower operation |
| Rollout switch | Manual-reset thermal fuse; match temperature rating |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the rollout switch tripped, do not simply reset it and move on. Rollout indicates that flames extended outside the burner box — caused by a blocked flue, blocked heat exchanger passages, or cracked heat exchanger. This is a carbon monoxide and fire hazard. Have a technician inspect before returning the furnace to service.