What Coleman furnace E2 means, why the pressure switch faults, and how to diagnose and fix it.
What Coleman furnace E2 means, why the pressure switch faults, and how to diagnose and fix it.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
E2 on a Coleman furnace (manufactured by York/Johnson Controls under the Coleman brand) indicates a pressure switch fault. The induced draft motor ran but the pressure switch did not close within the timed window, so the board blocked the ignition sequence. This is a safety interlock: without confirmed draft, the board will not open the gas valve.
| Part | Notes |
|---|---|
| Pressure switch | Match Coleman/York part number; check pressure rating |
| Pressure switch hose | 1/4” ID rubber or silicone; available in bulk |
| Inducer motor capacitor | Check before ordering a full motor assembly |
| Induced draft motor | Replace if capacitor is good but motor runs slow or noisy |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the flue is clear and the inducer runs at speed but the pressure switch still won’t close, have a licensed HVAC technician verify that the heat exchanger is not cracked (a crack can alter pressure differential in the flue) and that the pressure switch rating matches the furnace model requirements.