Carrier Furnace Blower Won't Shut Off - Causes & Fix

3 min read
⚡ Quick Answer

Usually the thermostat fan switch is set to ON instead of AUTO, or the thermostat is sending a constant 24V signal to the G terminal.

Difficulty Pro recommended
Est. time 1-3 hrs

Carrier Furnace Blower Won’t Shut Off — What’s Happening

A Carrier furnace blower that won’t shut off means the indoor blower is being told to keep running or the blower relay or control is stuck closed. This is not a single fault code but a symptom with several possible causes. The blower runs continuously even when there is no heating or cooling call, which points to either a control signal keeping it energized or a mechanical failure in the switching component.

Jump to Fix

Most Likely Causes

How to Diagnose and Fix

  1. Check the thermostat fan setting and confirm it is set to AUTO, not ON.
  2. Remove the thermostat from its wall base and observe whether the blower stops running (if it does, the thermostat or its wiring is the source).
  3. Measure voltage between the G and C terminals at the furnace control board with no heating or cooling call active (a present 24V signal means the blower is being commanded on).
  4. Disconnect the thermostat wiring at the furnace and recheck for 24V at G to isolate whether the issue is the thermostat, the wiring, or the furnace control.
  5. Inspect the thermostat cable for damaged insulation, shorts, or miswiring between G, R, and other low-voltage terminals.
  6. Inspect the fan relay on the control board or any external sequencer or fan limit control for welded or stuck contacts and replace the board or component if found.
  7. Replace the furnace air filter if dirty and verify that return and supply airflow paths are clear and unobstructed.
  8. Check the manual-reset rollout switch on the burner box and reset it only after correcting the airflow or overheating cause that led to the trip.

Parts You Might Need

PartNotes
Furnace control boardAmazon | Replace if the fan relay has welded contacts or is stuck closed.
ThermostatAmazon | Replace if internal switching is faulty or it sends a constant G signal.
ECM blower motor moduleAmazon | Required if the motor itself will not shut off despite proper control inputs.
Thermostat wire cableAmazon | Replace if shorted or damaged between terminals.

If your appliance also shows a code on the display, these match this problem:

When to Call a Pro

Call a professional if you are not comfortable working with 24V control wiring or 120V blower circuits, if the control board or blower motor module needs replacement, or if a rollout switch continues to trip after you have corrected airflow issues. Any work involving gas burners, ignition components, or repeated safety trips should be handled by a qualified HVAC technician. For gas line, burner, or igniter work, or if you ever smell gas, stop and call a licensed technician.