Cooling fan
Common VFD, drive, UPS, and cabinet overheating failure point.
Bosch Rexroth hydraulic fault codes for Sytronix, IndraControl, and proportional valve amplifiers: causes and repair steps.
Bosch Rexroth hydraulic fault codes for Sytronix, IndraControl, and proportional valve amplifiers: causes and repair steps.
Likely parts to price
Common VFD, drive, UPS, and cabinet overheating failure point.
Useful to price when faults involve display, keypad, or operator-panel behavior.
Low-cost first check for power-stage and line-side faults.
Price this on drive overvoltage, braking, or deceleration faults.
Bosch Rexroth hydraulic systems span Sytronix variable-speed pump drives, IndraDrive motion controllers, and electronic amplifiers for proportional/servo valves (VT-HACD, VT series).
| Code | System | Meaning | Quick Fix |
|---|---|---|---|
| F2002 | IndraDrive | Motor overcurrent | Check wiring and motor |
| F3102 | IndraDrive | DC bus overvoltage | Check brake resistor |
| F3104 | IndraDrive | DC bus undervoltage | Check supply voltage |
| F7010 | IndraDrive | Encoder feedback fault | Check encoder cable |
| F8022 | IndraDrive | Drive overtemperature | Check cabinet cooling |
| E01 | VT Amplifier | Enable input not active | Check enable wiring |
| E04 | VT Amplifier | Valve solenoid overcurrent | Check valve coil |
| E05 | VT Amplifier | Power supply out of range | Check 24VDC supply |
| Sytronix: DP High | HPU | Filter differential pressure | Replace filter element |
| Sytronix: Temp High | HPU | Oil temp exceeded | Check oil cooler |
Rexroth VT series amplifiers continuously monitor solenoid current. A short or open in the valve coil wiring or in the coil itself trips E04. Measure the solenoid coil with an ohmmeter - standard proportional solenoids measure 4–25 ohms. Values near zero indicate a short; infinite indicates open.
The IndraDrive requires clean, continuous feedback from the motor encoder. A failed encoder cable, damaged connector, or environmental contamination on encoder tracks generates F7010. Check the cable from the motor to the drive, especially near flex points and cable carriers.
On hydraulic press axes, rapid deceleration regenerates energy back into the DC bus. If the brake resistor is undersized, missing, or has failed open, the bus voltage spikes to F3102. Check the brake resistor with an ohmmeter - a failed resistor reads open.
Rexroth Sytronix pump drives monitor system pressure and can display filter differential warnings. Replace the hydraulic filter immediately and consider an oil sample to check contamination class. ISO 4406 cleanliness codes should be verified after any filter bypass event.
| Part | Notes |
|---|---|
| Hydraulic filter element (Rexroth) | Replace on DP high |
| Proportional valve coil | VT-DFP or DBEM coil assembly |
| Encoder cable (IndraDrive) | Replace on F7010 |
| Brake resistor module | Replace on F3102 |
| VT amplifier card | Replace on persistent E-faults |
Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
IndraDrive parameter sets and Sytronix pressure/flow curve tuning should be handled by Rexroth-trained engineers. Incorrect tuning can cause hydraulic instability or dangerous actuator runaway.