Skip to content
Industrial Error Code Fixes
Go back

Bosch Rexroth Hydraulic Fault Codes - Sytronix, Valves, and Amplifiers

⚡ Quick Answer

Bosch Rexroth hydraulic fault codes for Sytronix, IndraControl, and proportional valve amplifiers: causes and repair steps.

⚡ AT A GLANCEScroll down for full repair guide
What it meansBosch Rexroth hydraulic fault codes for Sytronix, IndraControl, and proportional valve amplifiers: causes and repair steps.
Most likely causeMost bosch-rexroth faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededCooling fan
Repair intent

Need this fixed instead of diagnosed?

Bosch Rexroth hydraulic fault codes for Sytronix, IndraControl, and proportional valve amplifiers: causes and repair steps.

Likely parts to price

Price the common parts before you book service.

Cooling fan

Common VFD, drive, UPS, and cabinet overheating failure point.

Control keypad

Useful to price when faults involve display, keypad, or operator-panel behavior.

Fuses

Low-cost first check for power-stage and line-side faults.

Braking resistor

Price this on drive overvoltage, braking, or deceleration faults.

Bosch Rexroth Hydraulic Fault Codes - Quick Reference

Bosch Rexroth hydraulic systems span Sytronix variable-speed pump drives, IndraDrive motion controllers, and electronic amplifiers for proportional/servo valves (VT-HACD, VT series).

CodeSystemMeaningQuick Fix
F2002IndraDriveMotor overcurrentCheck wiring and motor
F3102IndraDriveDC bus overvoltageCheck brake resistor
F3104IndraDriveDC bus undervoltageCheck supply voltage
F7010IndraDriveEncoder feedback faultCheck encoder cable
F8022IndraDriveDrive overtemperatureCheck cabinet cooling
E01VT AmplifierEnable input not activeCheck enable wiring
E04VT AmplifierValve solenoid overcurrentCheck valve coil
E05VT AmplifierPower supply out of rangeCheck 24VDC supply
Sytronix: DP HighHPUFilter differential pressureReplace filter element
Sytronix: Temp HighHPUOil temp exceededCheck oil cooler

Most Common Faults

VT Amplifier E04 - Solenoid Overcurrent

Rexroth VT series amplifiers continuously monitor solenoid current. A short or open in the valve coil wiring or in the coil itself trips E04. Measure the solenoid coil with an ohmmeter - standard proportional solenoids measure 4–25 ohms. Values near zero indicate a short; infinite indicates open.

IndraDrive F7010 - Encoder Feedback Fault

The IndraDrive requires clean, continuous feedback from the motor encoder. A failed encoder cable, damaged connector, or environmental contamination on encoder tracks generates F7010. Check the cable from the motor to the drive, especially near flex points and cable carriers.

F3102 - DC Bus Overvoltage

On hydraulic press axes, rapid deceleration regenerates energy back into the DC bus. If the brake resistor is undersized, missing, or has failed open, the bus voltage spikes to F3102. Check the brake resistor with an ohmmeter - a failed resistor reads open.

Sytronix Filter DP High

Rexroth Sytronix pump drives monitor system pressure and can display filter differential warnings. Replace the hydraulic filter immediately and consider an oil sample to check contamination class. ISO 4406 cleanliness codes should be verified after any filter bypass event.

Parts Often Needed

PartNotes
Hydraulic filter element (Rexroth)Replace on DP high
Proportional valve coilVT-DFP or DBEM coil assembly
Encoder cable (IndraDrive)Replace on F7010
Brake resistor moduleReplace on F3102
VT amplifier cardReplace on persistent E-faults

Need Replacement Parts?

Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

IndraDrive parameter sets and Sytronix pressure/flow curve tuning should be handled by Rexroth-trained engineers. Incorrect tuning can cause hydraulic instability or dangerous actuator runaway.


Share this post on:

Previous Post
Hydraulic System Fault Codes
Next Post
Parker Hydraulics Fault Codes - Complete Guide