Complete fault code guide for the Bosch IDS original series heat pump. Covers all error codes, diagnostic steps, and differences from the IDS 2.0 series.
Complete fault code guide for the Bosch IDS original series heat pump. Covers all error codes, diagnostic steps, and differences from the IDS 2.0 series.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
The Bosch IDS (Inverter Ducted Split) heat pump was a landmark product in the residential market — a variable-speed, communicating inverter heat pump offered at a mid-market price point before the IDS 2.0 replaced it. If you own an original IDS system, finding accurate fault code documentation can be difficult because Bosch has focused support resources on the newer platform. This guide covers all known fault codes for the original IDS series, explains key differences from the IDS 2.0, and gives you a clear diagnostic path for each fault.
The original Bosch IDS system communicates error conditions through the IDS Touch or IDS Basic thermostat display, the indoor unit’s LED, and the outdoor unit’s control board. Fault codes appear as alphanumeric codes on the thermostat and as blink sequences on the control board LEDs.
The IDS original uses a communicating system architecture — the thermostat, indoor air handler, and outdoor unit exchange data on a communication bus. This means a single fault at any component can generate secondary faults at the others. Always trace a fault back to its source component before replacing parts.
IDS Original vs. IDS 2.0 — Key Differences:
Common Bosch IDS Original Fault Codes:
| Code | Description |
|---|---|
| E1 | Indoor coil temperature sensor fault |
| E2 | Outdoor ambient temperature sensor fault |
| E3 | Discharge temperature sensor fault |
| E4 | High pressure protection activated |
| E5 | Low pressure protection activated |
| E6 | Communication fault (thermostat to indoor unit) |
| E7 | Communication fault (indoor to outdoor unit) |
| E8 | Indoor fan motor fault |
| E9 | Outdoor fan motor fault |
| F1 | Compressor overload protection |
| F2 | IPM (inverter module) overheat |
| F3 | DC bus overvoltage |
| F4 | DC bus undervoltage |
| F5 | Compressor overcurrent |
| F6 | Phase loss or reverse phase |
| H1 | Defrost in progress (normal operation indicator) |
| P1 | High discharge temperature lockout |
| P4 | Low ambient lockout (unit shut down due to temperature below operating range) |
1. E1 / E2 / E3 — Temperature Sensor Faults
Sensor faults are among the most common IDS codes. Before replacing sensors:
2. E4 — High Pressure Fault
High pressure faults indicate the refrigerant circuit is not rejecting heat properly in cooling mode, or absorbing heat properly in heating mode. Diagnose:
3. E5 — Low Pressure Fault
Low pressure faults typically indicate low refrigerant charge or a restriction in the system:
4. E6 / E7 — Communication Faults
These are the most frustrating faults to diagnose. Follow this sequence:
5. F1 / F5 — Compressor Faults
Compressor overload (F1) and overcurrent (F5) share common causes:
6. F2 — IPM Overheat
The Intelligent Power Module (inverter module) overheats when:
7. F3 / F4 — DC Bus Voltage Faults
These point to problems with incoming power quality or the inverter drive board:
| Part | Use | Amazon Link |
|---|---|---|
| NTC Temperature Sensor (10kΩ) | Replace failed E1/E2/E3 sensors | |
| HVAC Refrigerant Manifold Gauge Set | Diagnose E4/E5 pressure faults | |
| Low Voltage Thermostat Wire 18/5 | Replace communication wiring for E6/E7 | |
| Coil Fin Comb and Coil Cleaner | Clean outdoor coil for E4 and F2 faults | |
| Clamp Meter with True RMS | Measure compressor amperage for F1/F5 |
Need replacement parts? Search for parts and tools on Amazon.
Call a certified HVAC technician when:
Q: My Bosch IDS shows E7 constantly after a power outage. How do I clear it?
A: Power surges during outages can corrupt the control boards’ communication registers. Turn off the outdoor unit breaker, the indoor unit/air handler breaker, and the thermostat (or its circuit). Wait 5 full minutes, then restore power to the air handler first, then the outdoor unit, then the thermostat. This full power cycle clears most post-outage communication faults.
Q: How do I tell if I have an original IDS or an IDS 2.0?
A: Check the model number on the outdoor unit nameplate. Original IDS outdoor units typically start with BOVA (air-to-air) and have model numbers ending in a format like BOVA60HDN1. IDS 2.0 units have different model number structures and will have “IDS 2.0” on the unit’s label. You can also check the thermostat — IDS 2.0 ships with the BCC100 touchscreen thermostat.
Q: Can I use any communicating thermostat with the original Bosch IDS?
A: The original IDS uses a proprietary communication protocol. You must use the Bosch IDS Touch or IDS Basic thermostat for communicating control. Some installers have used the Bosch BCC100 in conventional (non-communicating) mode, but this disables variable-speed operation and fault reporting. Stick with the correct IDS thermostat.
Q: The H1 code shows during winter heating. Is my system broken?
A: No. H1 simply means the outdoor unit is in defrost mode — a completely normal operation in cold weather. The outdoor coil accumulates frost when ambient temperatures are between 17°F and 45°F with high humidity. The unit periodically reverses the refrigerant flow to melt the frost. H1 clears automatically when defrost completes, typically within 10-15 minutes.