Skip to content
Industrial Error Code Fixes
Go back

Bohn Refrigeration Error Codes - Temperature, Defrost, Sensor, and Fan Alarms

⚡ Quick Answer

Bohn unit-cooler alarms cover high box temperature, discharge temperature, suction pressure, defrost termination, fan motors, and sensors.

⚡ AT A GLANCEScroll down for full repair guide
What it meansBohn unit-cooler alarms cover high box temperature, discharge temperature, suction pressure, defrost termination, fan motors, and sensors.
Most likely causeMost refrigeration faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededTemperature sensor
Repair intent

Need this fixed instead of diagnosed?

Bohn unit-cooler alarms cover high box temperature, discharge temperature, suction pressure, defrost termination, fan motors, and sensors.

Likely parts to price

Price the common parts before you book service.

Temperature sensor

Common error-code part. Confirm resistance and connector style.

Thermistor

Useful to price for temperature-reading faults.

Thermal fuse

Low-cost safety part for heat and no-start symptoms.

Bohn Refrigeration Error Codes — What They Mean

Bohn is a Heatcraft Refrigeration Products brand, widely used in supermarkets, convenience stores, and food distribution walk-in coolers and freezers. Bohn unit coolers use the same electronic control platform as other Heatcraft brands (Larkin, Climate Control). The alarms and codes are identical across the Heatcraft product family.

AlarmMeaningUrgency
1High temperature alarmHigh
2High discharge temperatureHigh
3Low suction pressureMedium
4High suction pressureMedium
5Defrost termination faultMedium
6Evaporator fan motor faultHigh
7Temperature sensor faultMedium

Jump to Fix

Most Common Bohn Alarms and Fixes

Alarm 1 — High Temperature

Box temp exceeded setpoint. Immediate concern for product integrity. Check evaporator fan operation, coil ice level, door seals, and condensing unit.

Alarm 2 — High Discharge Temperature

Discharge line overheating. Check condenser cleanliness, condenser fan operation, refrigerant charge, and liquid line filter-drier restriction.

Alarm 5 — Defrost Termination

Defrost didn’t terminate at the expected temperature. Check defrost termination thermostat continuity and defrost heater element. On hot gas systems, check hot gas solenoid valve operation.

Alarm 6 — Fan Motor

Fan motor overload or failure. Replace if motor is seized. Check run capacitor on single-phase motors. Verify rotation direction after replacement.

Alarm 7 — Sensor

Air temperature sensor fault. Test NTC resistance, replace if open or shorted.

Parts Often Needed

PartNotes
Evaporator fan motorMatch to Bohn unit cooler model
Air temperature sensorBohn/Heatcraft NTC part
Defrost heaterMatch voltage and wattage
Defrost termination thermostatReplaces as a matched pair with heater

Need Replacement Parts?

Before ordering, match the refrigeration part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Alarms 3 and 4 require refrigerant circuit diagnosis by an EPA 608-certified technician.

Quick FAQ

Are Bohn and Heatcraft error codes the same?

Yes. Bohn is a Heatcraft Refrigeration Products brand, and Bohn unit coolers use the same electronic control platform as other Heatcraft brands like Larkin and Climate Control, so the alarm numbers and meanings are identical across the family.

What should I check first for a Bohn Alarm 1 high temperature alarm?

Check evaporator fan operation, coil ice level, door seals, and the condensing unit, in that order, since box temperature exceeding setpoint threatens product integrity and needs an immediate look.

Can I fix a Bohn Alarm 3 or 4 myself?

No. Alarms 3 (low suction pressure) and 4 (high suction pressure) require refrigerant circuit diagnosis by an EPA 608-certified technician, since they involve handling refrigerant.

What causes a Bohn Alarm 5 defrost termination fault?

Defrost termination faults mean defrost did not end at the expected temperature. Check the defrost termination thermostat continuity and the defrost heater element, and on hot gas systems also check the hot gas solenoid valve.


Need a professional? Compare Refrigeration repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Allen-Bradley PowerFlex F004 Fault - DC Bus Undervoltage
Next Post
Hoshizaki E7 Drain Valve Error Code