The Aprilaire 68 is a high-capacity whole-home dehumidifier (130 pints/day). It uses an electronic control board that displays fault codes on the unit’s LED status panel.
| Fault Code | Meaning | Quick Fix |
|---|---|---|
| E1 | Freeze protection — coil temperature too low | Check refrigerant charge and airflow |
| E2 | High pressure fault | Check condenser coil cleanliness and airflow |
| E3 | Compressor fault | Check compressor and electrical supply |
| Drain alarm | Drain line backup or float switch trip | Check drain line and float switch |
| Low airflow | Dirty filter or blocked airflow | Replace air filter |
| Sensor fault | Temperature sensor failure | Check sensor and replace |
The evaporator coil temperature has dropped below the freeze protection setpoint. The unit shuts down to prevent ice buildup. Causes:
Fix: Check and replace air filter. Confirm ambient temperature is above 55°F (typical minimum for dehumidifier operation). If filter is clean and ambient is correct, refrigerant charge may be low.
Discharge pressure is too high. On a dehumidifier, the condenser coils must be clean and have adequate airflow. Check:
The compressor is not running or has tripped on internal protection. Check:
The Aprilaire 68 requires filter replacement. A dirty filter is the root cause of E1 faults in most cases.
The Aprilaire 68 can gravity drain or use a condensate pump. If water backs up and the float switch trips:
| Part | Notes |
|---|---|
| Air filter | Most common maintenance item |
| Refrigerant charge | After confirmed E1 with clean filter |
| Start capacitor | Common on E3 compressor faults |
| Condensate pump | Replace if pump fails to discharge |
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Refrigerant work and compressor replacement require EPA 608 certification. Contact an Aprilaire dealer for warranty service.