A.O. Smith tankless temperature sensor
Part: 100109748
Inlet or outlet sensor for E05 and E06 faults.
A.O. Smith Signature 900 tankless error-code guide for ignition, flow, overheating, sensors, descaling, venting, and water-heater part checks.
A.O. Smith Signature 900 tankless error-code guide for ignition, flow, overheating, sensors, descaling, venting, and water-heater part checks.
Parts to price first
Part: 100109748
Inlet or outlet sensor for E05 and E06 faults.
Part: 100109749
Heat exchanger sensor for E07 and E08 faults.
Maintenance kit to address scale-related E04 overheating faults.
Ignition part to inspect for persistent E01 faults.
Flame-sense part to inspect for E01 or E02 faults.
Screen to clean or replace when low flow prevents ignition.
The A.O. Smith Signature 900 is A.O. Smith’s premium condensing tankless water heater line, available in 140,000–199,000 BTU configurations for whole-house applications. It’s a condensing unit with both primary and secondary heat exchangers, a stainless steel condensate management system, and A.O. Smith’s modulating gas valve that adjusts firing rate in real time based on incoming water temperature and flow rate. Fault codes appear on the digital display as E-series codes followed by a number. This guide covers E01 through E09, the full range of faults on the Signature 900 platform.
When the Signature 900 detects a fault, it shuts down, displays an E-code on the front panel LED display, and holds that code until either the condition clears (for auto-reset faults) or a manual reset is performed. The unit also has colored indicator LEDs: green for normal operation, yellow for minor alerts, and red for faults that have shut the unit down.
All E-codes have a specific origin, a sensor, a safety circuit, or a component that reported an out-of-range value. Understanding which component each code maps to makes diagnosis fast.
| Code | Fault Description | Reset Type |
|---|---|---|
| E01 | Ignition failure, no flame confirmed during startup | Manual |
| E02 | False flame detected, flame signal present when gas valve is closed | Manual |
| E03 | Gas supply or combustion fault, flame established but unstable | Manual |
| E04 | High temperature limit exceeded, heat exchanger overheated | Manual |
| E05 | Outlet water temperature sensor fault | Auto |
| E06 | Inlet water temperature sensor fault | Auto |
| E07 | Secondary heat exchanger temperature sensor fault | Auto |
| E08 | Heat exchanger outlet temperature sensor fault | Auto |
| E09 | Gas valve failure, valve not responding to modulation commands | Manual |
E01 is the most common fault on the Signature 900. It means the unit opened the gas valve and activated the igniter but never received a flame signal from the flame rod within the allowed startup window. The unit will attempt ignition 3 times before locking out on E01.
Root causes (in order of frequency):
On the Signature 900, the minimum water flow for ignition can be viewed in the diagnostic menu. Hold the Up and Down buttons simultaneously for 3 seconds to enter service mode, this displays current sensor values including flow rate.
E02 is unusual, it means the control board’s flame detection circuit is seeing a flame signal when the gas valve should be closed. This can mean:
Do not ignore E02. A confirmed flame rod short is usually harmless (just replace the rod), but a leaking gas valve is a safety issue that requires immediate professional service.
E03 fires when the unit establishes a flame but the flame signal is intermittent or drops out unexpectedly. This is the “almost-working” fault, the unit gets gas and ignites but can’t sustain reliable combustion.
Common causes:
The Signature 900 monitors water temperature at four points: the cold water inlet (E06), the hot water outlet (E05), the secondary heat exchanger (E07), and the primary heat exchanger outlet (E08). All four sensors are NTC thermistors. A sensor that has failed open will read –40°F or a similar extreme cold value; a shorted sensor reads 250°F or higher.
The Signature 900’s diagnostic mode (hold Up + Down for 3 seconds) displays live sensor temperatures. If a sensor shows –40 or 250 when at room temperature, it has failed.
A.O. Smith Signature 900 temperature sensors are 10k NTC thermistors. Part number 100109748 covers the outlet and inlet sensors; part number 100109749 covers the heat exchanger sensors, verify against your specific model’s parts list.
E04 means the primary heat exchanger outlet temperature exceeded the safety cutout (typically 203°F). This is the “something is very wrong with water flow or heat exchange” code. Root causes:
E09 specifically means the control board sent a modulation command to the gas valve’s stepper motor and received no response or an incorrect response. The Signature 900 uses a modulating gas valve, it doesn’t just open and close, it continuously adjusts gas flow to modulate BTU output.
E09 can also appear if:
Before condemning the gas valve, inspect and reseat the harness connector at both the valve and the board. E09 caused by a loose connector is a frustratingly common service call.
| Part | Why You Need It | Approx. Cost |
|---|---|---|
| A.O. Smith Tankless Temperature Sensor 100109748 | Inlet and outlet sensors; codes E05, E06, 10k NTC thermistor | $20–$45 |
| A.O. Smith Heat Exchanger Sensor 100109749 | Secondary and primary HX sensors; codes E07, E08 | $20–$45 |
| Tankless Descaler Flush Pump Kit | Critical for E04 faults in hard water areas; flush annually | $30–$65 |
| Igniter Electrode for AO Smith Tankless | Replace on persistent E01; check gap and ceramic insulator | $20–$50 |
| Flame Rod Sensor for Tankless Water Heater | Required for E01 or E02; shorted rod causes both fault types | $15–$35 |
| Water Heater Inlet Filter Screen | Clogged inlet filter causes E01 from low flow; clean or replace annually | $10–$20 |
Need replacement parts? Search for parts and tools on Amazon.
Certain Signature 900 faults must be handled by a licensed professional:
Sensor replacement, inlet filter cleaning, descaling, and igniter service are appropriate for a mechanically confident homeowner or general plumbing technician.
Q: My A.O. Smith Signature 900 shows E01 only during simultaneous hot water demand, like shower plus dishwasher. Why? A: Two most likely causes: (1) simultaneous demand is dropping gas supply pressure below the ignition minimum, measure dynamic pressure at the unit while firing, and (2) simultaneous demand exceeds the unit’s rated capacity, causing the unit to reduce flow sensing which dips below the minimum ignition threshold. A gas contractor can assess supply pressure; if the unit is legitimately undersized, a second unit or a buffer tank may be the answer.
Q: How do I descale my A.O. Smith Signature 900 at home? A: You need two things: a small submersible pump and several gallons of white vinegar (or commercial descaler). Connect the pump discharge to the unit’s cold inlet service valve with a hose, and connect the hot outlet service valve to a bucket or hose that drains back to the same bucket. Fill the bucket with vinegar, plug in the pump, and let it circulate for 45–60 minutes. Flush with clean water for 10 minutes, then disconnect. The service valves are pre-installed on the Signature 900 for exactly this purpose, no tools required except hose connections.
Q: Code E07 appeared after a power outage. The unit runs but the E07 light stays on. Should I be concerned? A: Code E07 (secondary heat exchanger sensor fault) that appeared after a power outage sometimes indicates a loose sensor connector that was disturbed. Turn off the unit and check the sensor wiring at the secondary heat exchanger, it’s typically a push-in connector near the bottom of the unit. Reseat it, restore power, and see if the fault clears. If the code returns, measure resistance at the sensor per the diagnostic steps above.
Q: What’s the annual maintenance schedule for the Signature 900? A: A.O. Smith recommends: (1) Annual descale in hard water areas (above 6 grains per gallon hardness), every 2 years otherwise. (2) Annual inlet filter screen inspection and cleaning. (3) Annual condensate drain and trap inspection, check that the trap has water in it and the drain line is clear. (4) Annual visual inspection of venting terminations for obstruction. (5) Every 3 years, check the anode rod if the unit has one (some Signature 900 configurations include an indirect storage tank, those have an anode rod).
E01 means the unit tried to ignite but did not confirm flame. Check gas supply, minimum water flow, igniter condition, flame rod, and combustion air intake before replacing parts.
Use the diagnostic mode to view live inlet, outlet, and heat-exchanger sensor temperatures. Extreme readings such as very cold or very hot values at room temperature point to an open or shorted thermistor.
E04 means the heat exchanger exceeded its high-temperature limit. Scale buildup, restricted flow, partially closed service valves, and flow-sensor problems are common causes.